THERMAFLOW LTD | THERMAFLOW® ELECTRIC COMBINATION BOILER |
Tel: 0870 850 5207
4.1.2 SOLID FUEL SYSTEM LINKED INTO THERMAFLOW
35
L
N
E
Supply
Manual Reset H/L
Thermostats
Automatic Air
Eliminators at high
points on pipe work
Pump
FE Tank
Solid Fuel
Stove
Gravity Radiator
Thermaflow external
primary heat transfer
Pump-set
For illustration purposes only
Temperature
ermostat
Control Th
Set 50˚C
Temperature
ermostat
Control Th
Set 70˚C