ENGLISH
Thermador Dishwasher Model DW 44Z
www.thermador.com
Electrical Preparation
•
Cut a 1” (25.4mm) diameter hole in the cabinet (in
area of Figure 9 B). For wood cabinets, sand the
hole until smooth. For metal cabinets, cover the
edge with a grommet.
•
Run flexible cable (as codes permit) from junction
through hole in cabinet. Cable should extend 30”
(762 mm) from back wall.
Electrical Supply
It is the customer’s responsibility to insure that the
dishwasher installation is in compliance with all natio-
nal and local electrical codes and ordinances. The
dishwasher is designed to operate with a 120V, 60Hz,
AC only electrical supply. Connect to a separate
electrical circuit with a fuse or circuit breaker rated
for 15 Amps. A 20 Amp fuse or circuit breaker may be
used if the dishwasher is connected with a food dispo-
ser, but not more than 20 Amps. Use Copper supply
conductors only. The dishwasher should be properly
grounded, positioned as shown in
Figure 9, and should
be installed by a qualified electrician. N o other
appliances or outlets should be connected to this cir-
cuit.
Openings for electrical lines must be in-
stalled in the marked areas as shown in Fig-
ures 8 and 9 to avoid interference with the
dishwasher frame or other components.
Electrical Rating
Table 2
Figure 9
Hot water supply line
Electric supply cable
Shut-off
valve
HW S
14"
(355 mm)
21"
(533 mm)
A
B
Figure 8
24"-24
-1
/
4
"
(610-616 mm)
THESE IN STALLATION
IN STRUCTION S ARE
IN TEN DED FOR USE BY
QUALIFIED IN STALLERS
WARNING
Volts
Hertz
Amperes
Watts
120
60
15
1,450
(max)
Page 7
3
-1
/
2
"
(90 mm)
1
-5
/
16
"
(49 mm)