CM Oven Service Manual
Lit. No. 94-30-006B
Page 107
THE HI-TEMP CUTOUT
The hi-temp cutout contacts open at or above 350˚F
±
8˚, and are manually reset by pressing the reset
button.
Refer to Page 93 to access the hi-temp cutout.
1.
With no power applied, remove the wires
from the terminals of the hi-temp cutout.
2.
Set the ohmmeter to the R x 1 scale.
3.
Touch the ohmmeter leads to the terminals.
The meter should indicate continuity.
4.
If the reading is not correct, remove and re-
place the hi-temp cutout.
Terminals
Hi-Temp Cutout
Reset Button
THE CONVECTION
BAKE ELEMENT
Refer to Page 88 to access the convection bake
element.
1.
With no power applied, remove the wires
from the terminals of the convection bake
element.
2.
Set the ohmmeter to the R x 1 scale.
3.
Touch the ohmmeter leads to the convection
bake element terminals. The meter should
indicate 18
Ω
.
4.
If the reading is not correct, remove and re-
place the convection bake element.