IS Unit Jumper Settings

At right are standard jumper settings for the Printed Circuit Board on the 

Internal Strainer Line of Big Dipper Units.

HEATER: Jumper on Position B for Silmutaneous Heat
AST: N/A
MODE (Skim Operation): Jumper on NORM for Normal Time-Based Operation

W-250-AST Jumper Settings

At right are standard jumper settings for the Printed Circuit Board on the 

W-250-AST.

HEATER: Jumper on Position B for Silmutaneous Heat
AST: Jumper on upper two pins; AST function operates 10 seconds every 24 hours
MODE (Skim Operation): Jumper on NORM for Normal Time-Based Operation

W-750-AST and W-1250-AST Jumper Settings

At right are standard jumper settings for the Printed Circuit Board on the 

W-750-AST and W-1250-AST.

HEATER: Jumper on Position B for Silmutaneous Heat
AST: Jumper on lower two pins; AST function operates 15 seconds every 2 hours
MODE (Skim Operation): Jumper on NORM for Normal Time-Based Operation

Rotisserie Operation Jumper Settings (for use with SWS)

At right are standard jumper settings for the Printed Circuit Board on Big 

Dipper units shipped with Supplemental Water Supplies for use with 

Rotisseries or Combi-Ovens.

HEATER: Jumper on Position B for Silmutaneous Heat
AST: N/A
MODE (Skim Operation): Jumper on ROT for Rotisserie/Thermistor Operation