26 

 

 

Heater produces a 
whistling noise when 
burner is lit.

 

 

Turning control knob to Hi 
position when burner is cold. 

 

Air in gas line. 
 
 

 

Air passageways on heater 
are blocked. 

 

Dirty or partially clogged 
burner orifice. 

 

Turn control knob to LO position 
and let warm up for a minute. 

 

Operate burner until air is 
removed from line. Have gas line 
checked by local gas supplier. 

 

Observe minimum installation 
clearances 

 

Clean or replace burner. 

 

Heater produces a 
clicking/ ticking noise 
just after burner is lit or 
shut off.

 

 

Metal is expanding while 
heating or contracting while 
cooling. 

 

 

This is common with most 
heaters. If noise is excessive, 
contact qualified service 
technician. 

 

White powder residue 
forming within burner 
box or on adjacent walls 
or furniture.

 

 

When heated, the vapors 
from furniture polish, wax, 
carpet cleaners, etc., turn 
into white powder residue. 

 

Turn heater off when using 
furniture polish, wax, carpet 
cleaner, or similar products. 

 

Heater produces 
unwanted odors.

 

 

Heater is burning vapors 
from paint, hair spray, glues, 
etc. See IMPORTANT 
statement. 

 

Gas leak. See Warning 
Statement   

 

Low fuel supply. 

 

Ventilate room. Stop using odor 
causing products while heater is 
running. 
 

 

Locate and correct all leaks, 
 

 

Refill supply tank (Propane / LP 
models). 

 

Heater shuts off in use 
(ODS operates).

 

 

 

Not enough fresh air is 
available. 

 

Low line pressure. 

 

ODS/pilot is partially 
clogged. 

 

Open window and/or door for 
ventilation. 

 

Contact local gas supplier. 

 

Clean ODS/pilot   

 

Gas odor during 
combustion

 

 

 

Gas leak. See Warning 
Statement   

 

Control valve is defective. 

 

Foreign matters in heater 

 

Locate and correct all leaks. 
 

 

Contact customer service. 

 

Remove foreign matters 

 

Unexpected 
moisture/condensation 
noticed on windows.

 

 

Ambient moisture is too high,   

 

Not enough ventilation 

 

Use a dehumidifier, 

 

R

efer to “Air for Combustion and 

Ventilation R

equirements” 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Содержание GLDF18M-V

Страница 1: ...r some of our most popular products without requiring any adjustments Our product lines consist of vent free gas wall heaters a direct vent gas wall heater line kerosene and propane forced air heaters...

Страница 2: ...ater WARNING Keep the appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids WARNING Due to high temperatures the appliance should be located out of t...

Страница 3: ...ings 13 The appliance must be isolated from the gas supply piping system by closing its equipment shut off valve during any pressure testing of the gas supply piping system at test pressures equal to...

Страница 4: ...d that has complied with all the requirement of the authority having jurisdiction PRODUCT FEATURES SAFETY PILOT This heater has a pilot with an Oxygen Depletion Sensing ODS safety shutoff system The O...

Страница 5: ...ate for heater location The Air Shutter is pre set for Liquid Propane use If using Natural Gas see Air Shutter section of manual Unit successfully tested o Installed by Company _______________________...

Страница 6: ...Compare parts with package contents list and diagram above If any part is missing or damaged do not attempt to assemble install or operate the product Contact customer service for replacement parts Be...

Страница 7: ...ater produces approximately one 1 ounce 30 ml of water for every 1 000 BTUs 0 3 KWs of gas input per hour Unvented room heaters are recommended as supplemental heat a room rather than a primary heat s...

Страница 8: ...f the aggregate input rating of all appliances installed in that space Rooms connecting directly with the space in which the appliances are installed through openings not furnished with doors are cons...

Страница 9: ...61 000 BTU Hr The space in the prior example is a confined space because the actual BTU hr used is more than the maximum BTU hr the space can support You must provide additional fresh air Your options...

Страница 10: ...quired size of ventilation grills or ducts Ventilation Air from Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two permanent openings one within 12 inches of th...

Страница 11: ...er creates warm air currents These currents move heat to wall surfaces next to heater Installing heater next to vinyl or cloth wall coverings or operating heater where impurities such as tobacco smoke...

Страница 12: ...arance in Figure 7 are not met you must have a hood When using a hood there are still certain minimum clearances required Follow minimum clearances shown in Figure 7 when using a hood The gas log heat...

Страница 13: ...anent vent opening at all times Damper manufacture shall recommend means to accomplish this such as by a screw or bolt in the edge of the damper to prevent its closing or by a hole or holes in the dam...

Страница 14: ...eater So you will need to flip it over I recommend laying a cloth down so that the metal of the burner does not rub on the floor You will want to look for an oval shaped cover that has two screws You...

Страница 15: ...lide any further Once done you will tighten the screw on the cylinder then seal the air shutter cover again For more information please visit our website www thermablaster com You can contact us at 87...

Страница 16: ...burner holes as this can lead to sooting and an overall drop in the performance of your heater Logs should be placed sequentially from lowest to highest as the numbering indicates There are grooves on...

Страница 17: ...to top of chimney and the minimum height is 10 feet Chart shows minimum opening sq in for the given height and input rate FOR MASONRY BUILT FIREPLACES Free Opening Area Of Chimney Damper For Venting C...

Страница 18: ...upply This heater requires an external regulator not supplied Install the external regulator between the heater and gas supply CAUTION Avoid damage to regulator Hold gas regulator with wrench when con...

Страница 19: ...1 Disconnect heater with its appliance main gas valve control valve and equipment shutoff valve from gas supply piping system Pressures in excess of 1 2 PSIG will damage heater regulator 2 Cap off ope...

Страница 20: ...WHAT TO DO IF YOU SMELL GAS Open the window or door immediately Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supp...

Страница 21: ...the Control Knob counterclockwise from the Pilot setting to the desired number setting This should be done slowly in one motion without stopping between positions Knob will only turn if you have a st...

Страница 22: ...22 Figure 12 Control Panel Figure 13 Pilot System Figure 14 Pilot Blue Flame...

Страница 23: ...pressed air in a can You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the directions on the can If you don t follow directions on the can you could dama...

Страница 24: ...your gas supplier call the fire department IMPORTANT Operating heater where impurities in air exist may create odors Cleaning supplies paint paint remover cigarette smoke cements and glues new carpet...

Страница 25: ...when control knob is released Both control and igniter knobs are not fully pushed down Thermocouples are not heated enough External shutoff valve of gas supply is not fully opened Thermocouple connec...

Страница 26: ...leaners etc turn into white powder residue Turn heater off when using furniture polish wax carpet cleaner or similar products Heater produces unwanted odors Heater is burning vapors from paint hair sp...

Страница 27: ...27 ILLUSTRATED PARTS Model GLDF18M V...

Страница 28: ...nt 31 Frame assembly 10 Nozzle seat 32 LP ODS 11 LPG Nozzle 33 Chamber spacer 12 NG Nozzle 34 Battery pack 13 Air door washer 35 Bottom Strengthen strip No 2 14 Air door rod 36 Bottom Strengthen strip...

Страница 29: ...ce Performed Service Date Please register your product online at www thermablaster com or send in the registration form below to our office at Reecon North America 2515 Liberty Ave Pittsburgh PA 15222...

Отзывы: