background image

12 

 

If Using Mantel

 

You must have noncombustible material(s) such as slate, marble, tile, 
etc. At least ½ in. thick. With sheet metal you must have 
noncombustible material behind it. Noncombustible material must 
extend at least 8 inches up. If noncombustible material is less than 12 
inches. you must install the fireplace hood accessory. Even if 
noncombustible material is more than 12 inches, you may need the 
hood accessory to deflect heat away from mantel shelf. See Figure 6, 7 
and 8. 

 
Mantel Clearances 

In addition to meeting noncombustible material clearances, you must 
also meet required clearances between fireplace opening and mantel 
shelf. If the clearances listed below are not met, you will need a hood. 

 

Determining Mantel Clearances 

If you meet minimum clearances requirements between mantel shelf 
and top of fire place opening, a hood is not necessary. See 
Figure 6.   
 

Determining Minimum Mantel Clearances When Using a 
Hood 

If minimum clearance in Figure 7 are not met, you must have 
a hood. When using a hood there are still certain minimum 
clearances required. Follow minimum clearances shown in 
Figure 7 when using a hood.   
 
The gas log heater must be installed at least 1 3/8” above 
any combustible flooring material, such as carpeting or tile, 
which is closer than 14” to the base of the fireplace. The minimum 
distance must be maintained from the top surface of carpeting, tile, 
etc. 

See Figure 8.

 

OR 

The  gas  log  heater  may  be  installed  nearer  to  the  floor  is  a 
minimum  of  14”  of  noncombustible  material  such  as  a  slate  or 
marble  is  installed  between  the  base  of  the  fire  place  and  the 
combustible flooring. 

See Figure 9.

 

 
When installing your log set as a vent free installation the damper 
clamp  can  be  used  to  eliminate  the  potential  for  odors  when 
burning the logs for the first time.   

 

IMPORTANT: 

If these minimum clearances are not met, you 

must operate heater with chimney flue damper open. Go to 

“Installing Damper Clamp”, page 13.

 

 
 
 

Figure  8  –  Minimum  Clearance  Above 
Combustible Flooring. 

Figure  6  –  Heat  Resistance  Material 
with No Hood 

Figure  7  –  Minimum  Mantel  Clearances 
with No Hood 

Содержание GLDF18M-V

Страница 1: ...r some of our most popular products without requiring any adjustments Our product lines consist of vent free gas wall heaters a direct vent gas wall heater line kerosene and propane forced air heaters...

Страница 2: ...ater WARNING Keep the appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids WARNING Due to high temperatures the appliance should be located out of t...

Страница 3: ...ings 13 The appliance must be isolated from the gas supply piping system by closing its equipment shut off valve during any pressure testing of the gas supply piping system at test pressures equal to...

Страница 4: ...d that has complied with all the requirement of the authority having jurisdiction PRODUCT FEATURES SAFETY PILOT This heater has a pilot with an Oxygen Depletion Sensing ODS safety shutoff system The O...

Страница 5: ...ate for heater location The Air Shutter is pre set for Liquid Propane use If using Natural Gas see Air Shutter section of manual Unit successfully tested o Installed by Company _______________________...

Страница 6: ...Compare parts with package contents list and diagram above If any part is missing or damaged do not attempt to assemble install or operate the product Contact customer service for replacement parts Be...

Страница 7: ...ater produces approximately one 1 ounce 30 ml of water for every 1 000 BTUs 0 3 KWs of gas input per hour Unvented room heaters are recommended as supplemental heat a room rather than a primary heat s...

Страница 8: ...f the aggregate input rating of all appliances installed in that space Rooms connecting directly with the space in which the appliances are installed through openings not furnished with doors are cons...

Страница 9: ...61 000 BTU Hr The space in the prior example is a confined space because the actual BTU hr used is more than the maximum BTU hr the space can support You must provide additional fresh air Your options...

Страница 10: ...quired size of ventilation grills or ducts Ventilation Air from Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two permanent openings one within 12 inches of th...

Страница 11: ...er creates warm air currents These currents move heat to wall surfaces next to heater Installing heater next to vinyl or cloth wall coverings or operating heater where impurities such as tobacco smoke...

Страница 12: ...arance in Figure 7 are not met you must have a hood When using a hood there are still certain minimum clearances required Follow minimum clearances shown in Figure 7 when using a hood The gas log heat...

Страница 13: ...anent vent opening at all times Damper manufacture shall recommend means to accomplish this such as by a screw or bolt in the edge of the damper to prevent its closing or by a hole or holes in the dam...

Страница 14: ...eater So you will need to flip it over I recommend laying a cloth down so that the metal of the burner does not rub on the floor You will want to look for an oval shaped cover that has two screws You...

Страница 15: ...lide any further Once done you will tighten the screw on the cylinder then seal the air shutter cover again For more information please visit our website www thermablaster com You can contact us at 87...

Страница 16: ...burner holes as this can lead to sooting and an overall drop in the performance of your heater Logs should be placed sequentially from lowest to highest as the numbering indicates There are grooves on...

Страница 17: ...to top of chimney and the minimum height is 10 feet Chart shows minimum opening sq in for the given height and input rate FOR MASONRY BUILT FIREPLACES Free Opening Area Of Chimney Damper For Venting C...

Страница 18: ...upply This heater requires an external regulator not supplied Install the external regulator between the heater and gas supply CAUTION Avoid damage to regulator Hold gas regulator with wrench when con...

Страница 19: ...1 Disconnect heater with its appliance main gas valve control valve and equipment shutoff valve from gas supply piping system Pressures in excess of 1 2 PSIG will damage heater regulator 2 Cap off ope...

Страница 20: ...WHAT TO DO IF YOU SMELL GAS Open the window or door immediately Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supp...

Страница 21: ...the Control Knob counterclockwise from the Pilot setting to the desired number setting This should be done slowly in one motion without stopping between positions Knob will only turn if you have a st...

Страница 22: ...22 Figure 12 Control Panel Figure 13 Pilot System Figure 14 Pilot Blue Flame...

Страница 23: ...pressed air in a can You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the directions on the can If you don t follow directions on the can you could dama...

Страница 24: ...your gas supplier call the fire department IMPORTANT Operating heater where impurities in air exist may create odors Cleaning supplies paint paint remover cigarette smoke cements and glues new carpet...

Страница 25: ...when control knob is released Both control and igniter knobs are not fully pushed down Thermocouples are not heated enough External shutoff valve of gas supply is not fully opened Thermocouple connec...

Страница 26: ...leaners etc turn into white powder residue Turn heater off when using furniture polish wax carpet cleaner or similar products Heater produces unwanted odors Heater is burning vapors from paint hair sp...

Страница 27: ...27 ILLUSTRATED PARTS Model GLDF18M V...

Страница 28: ...nt 31 Frame assembly 10 Nozzle seat 32 LP ODS 11 LPG Nozzle 33 Chamber spacer 12 NG Nozzle 34 Battery pack 13 Air door washer 35 Bottom Strengthen strip No 2 14 Air door rod 36 Bottom Strengthen strip...

Страница 29: ...ce Performed Service Date Please register your product online at www thermablaster com or send in the registration form below to our office at Reecon North America 2515 Liberty Ave Pittsburgh PA 15222...

Отзывы: