Parameter

Description

Can be 

queried 

SendoPro

868-A

Can be 

changed 

SendoPro

868-A

Can be 

changed 

theSenda 

P

Brightness 

switching 

value A

Value range in lux

x

x

x

Measurement off

x

x

x

Room correc-

tion factor A

Room correction 

factor

x

Brightness 

actual value A

Query brightness 

actual value

x

Light 

measurement

Selection: wide / spot x

x

Time delay A

Value ranges in 

seconds / minutes

x

x

Pulse

x

x

Short presence 

A

Short-term presence: 

On/Off

x

Time delay H

Value ranges in 

seconds / minutes

x

x

Switch-on 

delay H

Value ranges in 

seconds / minutes

x

Assignment 

channel A

Assignment function 

relay H: L‘ / L‘ + H / H

x

Energy saving 

mode

Selection: eco / eco 

plus

x

x

Configuration 

type

Selection: auto / man x

x

x

Staircase light 

function

Selection: Off / On

x

Control input S

Auto / switch / push 

button S / push 

button O

x

Detection 

sensitivity

Detection

Sensitivity

(PIR): value range in

Increments

x

x

Monitoring 

sensitivity 

reduction

Room monitoring 

sensitivity: value 

range in

Increments

x

Group address

Selection: I / II / III 

/ all

x

Scene 1

Off / On

x

Scene 2

Off / On

x

LED display 

motion

Off / On

x

The parameters are sent to the presence detector with the 

"SendoPro 868-A" management remote control or with "the-

Senda P" installation remote control via infra-red. Changed 

parameters are immediately applied and used by the detector. 

With the "SendoPro 868-A" management remote control, 

parameters can be queried by sending values level-by-level 

to the detector. If the sent value is below the set parameter, 

the LED illuminates briefly. If the sent value is equal or above 

the set parameter, the LED flickers for 2 seconds.

The following control commands can be triggered 

with the remote control:

Control 

command

Description

Can be 

triggered 

SendoPro

868-A

Can be 

trigge-

red the-

Senda P

Teach-in chan-

nel A

Activation

x

x

Switching light

Lighting group can be switched 

on and off.

x

x

Control 

command

Description

Can be 

triggered 

SendoPro

868-A

Can be 

trigge-

red the-

Senda P

Presence test 

Off / On

x

x

Light test

Off / On

x

Restart

Restart detector

x

x

Local settings

Detector assumes the set-

tings of the DIP switch and all 

potentiometers

x

Factory 

settings

Set all parameters and settings 

to factory setting.

x

Brightness switching value A

The brightness switching value defines the minimum desired 

brightness. The currently prevailing brightness is measured 

below the presence detector. If the prevailing brightness 

is below the switching value, the light switches on when a 

presence is detected (in configuration type fully automatic 

device).

Value range

Lux values with "SendoPro 868-A" management remote 

control

In the installation remote control "theSenda P", the 

following values are available

(The currently measured brightness value (Lux) can 

be adopted with the "SendoPro 868-A" management 

remote control, with the teach-in control command or 

with the “theSenda P” installation remote control via the 

teach-in button.)

Values outside the permitted range will automatically be 

set to the appropriate limit value.

5 - 3000 lux

5, 10, 15, 300, 

500, 800 lux

- Deactivating the brightness measurement (the bright-

ness has no influence)

- The light channels only switch according to presence/

absence.

Possible with "SendoPro 868-A" management remote 

control or "theSenda P" installation remote control.

Measurement 

off

Button 

Room correction factor A

The room correction factor is a measurement for the diffe-

rence of the brightness measurement on the ceiling and the 

work area. The brightness measurement value at the ceiling 

is influenced by the installation location, incidence of light, 

position of the sun, weather conditions, the reflection proper-

ties of the room, and the furniture.

With the room correction factor, the measured brightness 

value of light channel A is adjusted to the conditions in the 

room and in this way can be matched to the lux meter value 

 measured at the surface beneath the presence detector.

Room correction factor = Brightness value at the ceiling / 

brightness value at the working surface

Содержание thePrema P360-101 E UP WH

Страница 1: ...option Installation remote control theSenda P option 2 Safety Danger of death through electric shock or fire Installation should only be carried out by a qualified electrician WARNING Work on electric...

Страница 2: ...is switched off automatically Staircase light function The staircase light function can be set to room or corridor using the DIP switch or the SendoPro management remote control Lighting can be switch...

Страница 3: ...0 m 100 m2 10 0 m x 10 0 m 1 0 m Brightness measurement The presence detector measures artificial light and daylight that is reflected below the detector The character of the light measurement can be...

Страница 4: ...ce detector is insufficient larger rooms then up to 10 detectors can be operated in parallel by connecting P terminals In the process presence detection is performed by all detectors together The mast...

Страница 5: ...area covered by one presence detector is insuffi cient larger rooms then up to 10 presence detectors can be operated in parallel as slaves by connecting P terminals Master switches lighting directly...

Страница 6: ...function see function description room manual switching on and off possible corridor detector is used as staircase light timer switch Manual switch off is no longer possible DIP switch energy saving b...

Страница 7: ...on Can be triggered SendoPro 868 A Can be trigge red the Senda P Presence test Off On x x Light test Off On x Restart Restart detector x x Local settings Detector assumes the set tings of the DIP swit...

Страница 8: ...n Adjustable values theSenda P 10 s 30 s 60 s 2 min 10 min 20 min 120 min Switch on delay H The presence channel always switches regardless of whether configuration type is set to fully automatic devi...

Страница 9: ...ed when using the theSenda S user remote control A group address can be assigned to Channel A light The SendoPro 868 A or theSenda S can be used to pro gram the group addresses in the detector Group a...

Страница 10: ...not be activated in test mode Test mode ends automatically after 10 min The detector performs a new start see switch on behaviour Light test The light test mode is used to check the brightness thresho...

Страница 11: ...incandescent lamps halogen spotlights moving objects e g curtains hanging in an open windows Load EBs relays not cleared Push button does not function Device still in the start up phase illuminated pu...

Страница 12: ...ww theben de SendoPro 868 A Item No 9070675 Details www theben de theSenda S Item No 9070911 Details www theben de theSenda P Item No 9070910 Details www theben de ThebenHTS AG Im Langhag 7b 8307 Effr...

Отзывы: