18
ENGLISH
3.2
Mounting and Electrical Connection
3.2.1 Connection (and mounting) of the temperature
floor sensor
– The temperature floor sensor should be placed in the floor in a
„PVC“ tube between the heating cables.
– The sensor device cable must not be laid together with a voltage-
carrying cable in an empty tube.
Attention!
– Make use of a original floor sensor only!
– The sensor cable should not be lengthened!
– The sensor cable may be shortened. before doing so, make sure that
the temperature regulator is disconnected!
– We strongly recommend to implement on extra security for the
regulator system through installing a personal protection switch!
RAMSES 818 top 16 A
RAMSES 818 top 6 A
3.2.2 Connection examples RAMSES® 818 top 6 A
3.2.3 Connection examples RAMSES® 818 top 16 A
flush-mounted
socket
N
L1
heating cable
Regulation of an
underfloor hea-
ting cable or a
heating mat
Heating mat
Connection
– Remove the connection cable from the terminal.
– Now attach the connection cable (see figure).
Connect the temperature sensor according to the connection diagram.