22
4. Setting the optimisation
The optimisation function allows you to achieve a certain
room temperature at a desired switching point. The display
shows how many minutes earlier the heating starts. This time
applies per K of temperature difference between actual tem
-
perature and desired set temperature.
Example
At 06.00 a.m. in the morning, a change in the bathroom is
programmed from reduction (17 °C) to comfort temperature
(23 °C).
Without optimisation function, the room thermostat enables
the heating request for the bathroom at 06.00 a.m. Depen
-
ding on the size of the room and the installed heating system,
the bathroom reaches the desired 23 °C at 6.30 a.m., for
example.