2
L2
L1
L
If the bezel frame is mounted as shown in the figure, the
alignment of the light measurement can also be identified
when it is installed. The arrow marking shows where light
measurement L2 is.
Disconnect the power source prior to installation.
Installation in false ceiling (ceiling installation)
Create a ceiling opening of approx. Ø 68 mm.
Strip the cable to 6 – 8 mm.
Assemble and connect the device as shown in the figure.
Ø = 68
6 - 8 mm
30 - 35 mm
Screws
Flush mounting
Remove the ceiling installation box from the detector.
Strip the cable to 6 – 8 mm.
Assemble and connect the device as shown in the figure.
6 - 8 mm
20 - 30 mm
Decorative
frame
Turn left to
take off
Non-dropping
screw
Fixing plate
Detector
Secured
screws
Turn anticlockwise
and remove
Decorative
ring
Detector
Installation
frame
L
A box with a minimum depth of 40 mm provides the opti
-
mum installation conditions.
Surface mounting
Strip the cable to 6 – 8 mm.
Assemble and connect the device as shown in the figure.
L
IP 54 protection.
6 - 8 mm
30 - 35 mm
Decorative
frame
Turn left to
take off
Non-dropping
screw
Detector
Secured
screws
Turn anticlockwise
and remove
Decorative
ring
Detector
Surface-mount
frame 9070819
Detection area
A
S
T
Installation
height (A)
Walking persons
frontal (r)
Walking persons
across (t)
Seated persons
(s)
2.5 m
28 m
2
Ø 6 m
452 m
2
Ø 24 m
28 m
2
Ø 6 m
All figures are guidance values.
Limiting the detection area
Use
the enclosed cover clip to adjust the detector to the
desired detection area.
Remove the required section of the clip using scissors.
Then place it on the lens.