DMX Start Address Thumbwheel 

Valid DMX start address:   12 Chn: 1-501; 6 Chn: 1-507 
Invalid DMX start address: 12 Chn: 0, 502-999; 6 Chn: 0, 508-999 
 
If an invalid address is selected the start address defaults to 1. 
 

DMX Fail behaviour 

Last DMX levels retained until power off 
All DMX levels initialised to zero at power on  
 

Temperature LED behaviour

 with heatsink temperature: 

LED Off: 

 

under 50 degrees C 

LED 2 sec Flash: 

between 50 and 59 degrees C 

LED On 

 

between 60 and 69 degrees C 

LED Rapid Flash 

70 degrees C or over: all Channels are switched Off   

 

Fan behaviour

 with heatsink temperature 

30 degrees C: 

Fan starts at 50% speed 

- then fan speed increases with each degree C to - 
35 degrees C: 

Fan at 100% speed 

 
The fan stays on for 10 minutes after the internal temperature drops below 30 
degrees 

 
SwitchPack behaviour at power on: 

All LEDs set On for 1 second 
Fan set On at 100% for 1 second 
All Channels set Off for 1 second 

 
SwitchPack behaviour 1 second after power on: 

DMX LED shows DMX state 
Phase ABC LEDs show power state 
Temp LED shows temperature state 
On/Off/DMX mode restored to the original settings before power off 
DMX security mode restored to the original settings before power off 
Keyboard enable/disable state restored to the settings before power off 
 
Note: if power goes off before the 5 minutes timeout of Parameter Save above, the 
new settings will be lost. 
 

 

Содержание SwitchPack 1210 DMX

Страница 1: ...he SwitchPack DMX is a reliable DMX controlled mains power supply for LED luminaires moving lights and other inductive and capactive loads It is available in three versions SwitchPack 1210 12 channels at 10 amps SwitchPack 1220 12 channels at 20 amps and SwitchPack 630 6 channels at 32 amps with terminal or a selection of socket backs SwitchPack 1210 and 1220 SwitchPack 630 ...

Страница 2: ...load This results in a very low DC component to protect magnetic transformers from core saturation and consequent fire hazard SCRs are voltage surge and spike protected Overload limited by thermistor channels are switched off on long term over current to limit damage due to over heating Minimum volts loss to load only 1 5 volts On or Off states may be controlled by DMX remotely or locally from the...

Страница 3: ...ays On Key LED blinks off briefly 3 Channel on DMX control Key LED is either on or off not blinking depending the DMX control level for that channel The DMX levels have hysteresis levels fixed at On at 60 and Off at 40 The behaviour is If Off the channel is only set On if the DMX level exceeds 60 If On the channel is only set Off if the DMX level drops below 40 The On time and Off response time de...

Страница 4: ... bottom centre Keys until you see a short flash of all mimic LEDs about 10 secs the keys are now enabled Set all Channels On Off DMX 12 chn only Hold Key 1 then press Key 2 after a short flash all Channels are set Off all Key LEDs blink on Key 3 after a short flash all Channels are set On all Key LEDs blink off Key 4 after a short flash all Channels are set to DMX control All Key LEDs are either o...

Страница 5: ... C or over all Channels are switched Off Fan behaviour with heatsink temperature 30 degrees C Fan starts at 50 speed then fan speed increases with each degree C to 35 degrees C Fan at 100 speed The fan stays on for 10 minutes after the internal temperature drops below 30 degrees SwitchPack behaviour at power on All LEDs set On for 1 second Fan set On at 100 for 1 second All Channels set Off for 1 ...