background image

 

                

www.theatrelight.co.nz 

 

Theatrelight NZ

PO Box 13-159, Onehunga, Auckland, New Zealand

6 Rowe St, Onehunga, Auckland, New Zealand

Tel: 64-9-622 1187, Fax: 64-9-636 5803,

 
 

Switchpack DMX Operation 

 
 

DMX Address setup 

 
The DMX start address for each Switchpack is set by the 3 digit thumbwheel. 
 
For example if the thumbwheel is set 001, then DMX channels 1-12 will control 
SwitchPack outputs 1-12 etc. A second SwitchPack should have its DMX start 
address set to 013, so its outputs follow DMX channels 13-24 etc. 
 
Valid thumbwheel settings are 1-501 for the 12 channel version, and 1- 507 for the 6 
channel version.   
 

On/Off/DMX Mode set per channel: 

 
Press any Key- the Channel cycles through 3 states: 
1/ Channel always Off - Key LED blinks on briefly 
2/ Channel always On  - Key LED blinks off briefly 
3/ Channel on DMX control- Key LED is either on or off (not blinking) depending the 
DMX control level for that channel 
 

 

The DMX levels have hysteresis levels fixed at On at 60%, and Off at 40%. The 
behaviour is: 
  
 

If Off, the channel is only set On if the DMX level exceeds 60% 

 

If On, the channel is only set Off if the DMX level drops below 40% 

 
The On time and Off response time depends on the security time settings described 
below.  
 

DMX Security Modes

 (6 and 12 chn): 

Enhanced security delays may be chosen so that received DMX levels are averaged 
over time. The longer time settings provide greater security to accidental changes in 
the SwitchPack outputs: 
 
Hold two middle centre Keys for 2 secs, then release Keys on a short flash- the fast 
flashing LED shows the current DMX security setting: 
LEDs   

             1             2        3        4         5        6 

0-Full times (secs)      Instant   0.15s  0.3s   0.75s  1.5s   3s 
 
 
Press a new Key 1-6 to change to a new DMX security setting. 
 

Содержание SwitchPack 1210 DMX

Страница 1: ...he SwitchPack DMX is a reliable DMX controlled mains power supply for LED luminaires moving lights and other inductive and capactive loads It is available in three versions SwitchPack 1210 12 channels at 10 amps SwitchPack 1220 12 channels at 20 amps and SwitchPack 630 6 channels at 32 amps with terminal or a selection of socket backs SwitchPack 1210 and 1220 SwitchPack 630 ...

Страница 2: ...load This results in a very low DC component to protect magnetic transformers from core saturation and consequent fire hazard SCRs are voltage surge and spike protected Overload limited by thermistor channels are switched off on long term over current to limit damage due to over heating Minimum volts loss to load only 1 5 volts On or Off states may be controlled by DMX remotely or locally from the...

Страница 3: ...ays On Key LED blinks off briefly 3 Channel on DMX control Key LED is either on or off not blinking depending the DMX control level for that channel The DMX levels have hysteresis levels fixed at On at 60 and Off at 40 The behaviour is If Off the channel is only set On if the DMX level exceeds 60 If On the channel is only set Off if the DMX level drops below 40 The On time and Off response time de...

Страница 4: ... bottom centre Keys until you see a short flash of all mimic LEDs about 10 secs the keys are now enabled Set all Channels On Off DMX 12 chn only Hold Key 1 then press Key 2 after a short flash all Channels are set Off all Key LEDs blink on Key 3 after a short flash all Channels are set On all Key LEDs blink off Key 4 after a short flash all Channels are set to DMX control All Key LEDs are either o...

Страница 5: ... C or over all Channels are switched Off Fan behaviour with heatsink temperature 30 degrees C Fan starts at 50 speed then fan speed increases with each degree C to 35 degrees C Fan at 100 speed The fan stays on for 10 minutes after the internal temperature drops below 30 degrees SwitchPack behaviour at power on All LEDs set On for 1 second Fan set On at 100 for 1 second All Channels set Off for 1 ...