![THE SHOWER LAB VIEW 09 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/the-shower-lab/view-09/view-09_manual_1100505012.webp)
03/2021 V 1.0
VIEW 09
04/20
Remove and replace the Panel adding
or subtracting spacers as necessary to
level the Panel (to a maximum height
of 5mm inside the Underframe).
Check the Panel is level using a Spirit
Level.
Align the Return Panel so there is a
4mm gap between the Panel and the
front face of the Front Underframe.
Using purpose built “Glass Lifters”,
carefully place the Inline Panel on to
the Underframe Gasket and push
against the Wall Profile.
Note the orientation and position of
the Panel, this can be determined by
any holes or attached labels.
Remove and replace the Panel adding
or subtracting spacers as necessary to
level the Panel (to a maximum height
of 5mm inside the Underframe).
Check the Panel is level using a Spirit
Level.
If the difference between the two
Panels is greater than 5mm, it may be
necessary to lower the Return Panel.
13
14
15
16
4mm