WARNING
This product should be installed
and serviced only by
a qualified pool
professional.
FILTER DISASSEMBLY INSTRUCTIONS
1. Turn off all system circulation pumps
and all electric
power on the equipemt
pad.
2. Set all system valves in a position to
prevent water flow to
the filter.
3.The manual air relief valve must be
placed in the OPEN
position. (Fig 6)
4. Remove filter drain plug (Fig 4) and
drain water from filter.
5. Using 3/4” wrenches or hex sockets,
loosen and remove the clamp nut
and
the clamp bolt. (Fig 5)
6. Holding both ends of the filter clamp
carefully spread the clamp ends.
Remove the clamp by lifting over the
upper filter body. Do not to drop the
clamp during removal, because the
clamp could be damaged. Do not
strike
the clamp with metal tools as they can
damage the clamp.
7. Lift off upper filter body. Do not use the
pressure gauge to lift the upper
filter
body.
MAINTAINING YOUR FILTER
REMOVING
CARTRIDGES
1. Remove the top Manifold, which is
exposed when the upper filter body i
removed. (Fig 4)
2. Remove the filter cartridge elements b
using slight rocking motion and lifting up.
3. Clean filter cartridge elements
DRAIN PLUG
WITH O-RING
O-RING
MANIFOLD
LOWER BODY
Figure 4
Figure 5
Figure 6
Manual Air Relief shown open