OPERATION
DANGER
Keep clear of moving parts! To be operated by one person only!
AIR BLEEDER
IMPORTANT
Before operating the log splitter, the Air Bleeder should be loosened a few rotations until air can go
in and out of the oil tank smoothly. Air flow through the Air Bleeder should be noticeable when the
log splitter is working. Before moving the log splitter, make sure the Air Bleeder is tightened to avoid
oil leaks.
FAILURE TO LOOSEN THE AIR BLEEDER WILL KEEP THE SEALED AIR IN THE HYDRAULIC SYSTEM
COMPRESSED. SUCH CONTINUOUS AIR COMPRESSION WILL BLOW OUT THE SEALS OF THE
HYDRAULIC SYSTEM AND CAN CAUSE PERMANENT DAMAGE TO THE LOG SPLITTER, WHICH IS NOT
COVERED UNDER THE TERMS & CONDITIONS OF THE MANUFACTURERS WARRANTY.
CHECK THE HYDRAULIC OIL LEVEL
The hydraulic system is a closed system with oil tank, oil pump and control valve. Check the oil level
regularly with the dipstick, located on the Air Bleeder. Low oil levels can damage the oil pump. Oil
Level should measure approx. 1 - 2 cm lower than the upper surface of the oil tank.
Oil level
Read dipstick to determine the maximum and minimum of the oil level. Low oil can
damage the oil pump. Overfilling can result in excessive temperature in the
hydraulic transmission system
.