Airplane Factory SLING LSA
Pilot Operating Handbook
Page | 7-23
Date of Issue: 07 July 2014
Revision : 1.3
With regard to the above:
1.
The EFIS and related equipment (iBOX, RDAC) can be operated via
the EFIS back-up battery circuit, provided that the circuit is switched
on and the back-up battery contains adequate charge.
EFIS back-up battery / circuit
The 12 V EFIS back-up battery is mounted on the cabin side of the firewall,
under the instrument panel. The EFIS back-up circuit can be operated
independently from the main bus (i.e. with power to the main bus
unavailable).
Master and starter switch(es)
See the applicable supplement at the end of this manual with regard to
the Master / starter switch(es) on 912 iS equipped aircraft.
The master switch and starter switch(es) are incorporated into a key
switch mounted on the instrument panel. Refer to paragraphs 7.10, 7.17.1
and 7.17.2.
The master / starter switch provides the following functionality:
•
Connects the main bus to the 12 V main battery / charge system.
•
Activates the starter motor.