118
ProMark2 User’s Guide
Site Description Screen
The
Site Description
screen, Figure 4.11, can be accessed from the
Point Attribute
screen
when the
Site Description
field is highlighted and the
Enter
key is pressed.
The
Site Description
screen lets you select a descriptor from the descriptor list, enter a new
descriptor, edit an existing descriptor, and delete a descriptor. The descriptor can be 20
characters in length. The site description table allows up to 16 site descriptors on the list. The
default value <Empty> will always be available in the list. <Empty> will allow you to set the
site descriptor field to an empty string. Table 4.8 describes the screen parameters.
Figure 4.11
Site Descriptor Screen
Table 4.8
Site Descriptor Screen Parameters
Parameter
Description
Save
Saves the data entry, sets the highlighted descriptor in the
Site Descriptor
field in the
Point Attribute
screen, and returns the program to the
Point Attribute
screen.
New
Calls the
Description Edit
screen where you can enter a descriptor up to 20 characters
in length. This field is no longer selectable when 16 descriptors are in the table.
Edit
Calls the
Description Edit
screen where you can modify the highlighted descriptor.
Delete
Deletes the highlighted descriptor. Descriptors can only be deleted one at a time.
Note: Press the
ESC
button to cancel changes and return to the
Point Attribute
screen. The table is saved
after a power cycle with all entries in the
Site Description
screen that have been saved. Save button has been
pressed.