background image

10C Maurice Rd   

PO Box 26353 

 

Tel: 09 5251875   

 

 

 

Penrose 

  Epsom 

  Fax: 

09 

5251874 

    

Auckland, New Zealand 

Auckland 

 

Email: [email protected] 

 

4.4 Upper limit and lower limit temperature alert 

To set an upper temperature limit, that means when passing the temperature an alarm is beeping, 
press the AL SET-button. The upper temperature limit 

t

is flashing. Set the desired temperature by 

pressing the +1-button. Hold and press the button for a fast count. Now you can activate (alarm 
symbol appears) or deactivate (alarm symbol disappears)  the alarm pressing MAX/MIN- button. 
Confirm by pressing the AL SET –button. 

The lower temperature limit 

u

is flashing. To set a lower temperature limit, that means when falling 

below the temperature an alarm is beeping,  press +1-button. Hold and press the button for a fast 
count. Now you can activate or deactivate the alarm pressing MAX/MIN- button. Confirm by pressing 
the AL SET –button. 

After setting temperature alarm the symbols 

show, if an upper or lower temperature alarm is 

activated.  

When passing or falling below the selected temperature limit an alarm signal will sound for 1 minute,  
the buzzer alarm icon and the corresponding arrow 

t

or

u

will flash. The alarm and the buzzer alarm 

icon can be turned off manually by pressing any button.  

When temperature is again within the selected limits the alarm signal will stop (within 1 min.) and the 
buzzer alarm flashing icon disappears. The arrow keeps on flashing showing that the temperature 
was higher/lower than the preset value at least once in the past. Press +1- button and the arrow will 
stop flashing.  

 
5. Battery change 

When the battery is used up, low battery icon appears.  
Open the battery cover on the backside of the instrument, insert a new battery CR2032 3V Lithium and 
close the cover.  

Attention:

 Please do not dispose of old electronic devices and used batteries in household waste.  

To protect the environment, take them to your retail store or to nearest civic amenity site to be disposed 
of according to national or local regulations.  

 
6. Technical data 

 

LT-101 (30.1033) 

LT-102 (30.1034) 

Measuring range  

-40 °C to +200°C (reversible °C/°F) 

-50 °C to +70°C (reversible °C/°F) 

Precision:                +/-0.5°C from 0 to 50°C, 

+/-1°C from -20 to 0°C, 51 to 70°C   
+/-2°C from -40 to -20°C, 70 to 200°C 

+/-0.5°C from -20 to +25°C, 
+/-1°C Rest 

Cable:  

 

Approx 1m 

     Approx. 3m 

Resolution: 

  

     0,1°C 

     0,1°C 

Battery:                 

 

CR2032 3V Lithium button cell battery 

CR2032 3V Lithium button cell battery 

Measurements:      c. 86 x 57 x 30 mm 

c. 86 x 57 x 30 mm 

7. Attention

 

Do not place the display unit near extreme temperatures. Only the probe is heat resistant. 

Do not immerse the display unit into water, water can penetrate and cause malfunction. 

Please do not try to repair the unit. Contact the original point of purchase. Please change the battery 
before complaining. No guarantee if the instrument is handled or opened improperly. 

 

Отзывы: