HE.15323_C © 06/2014
6
AHP 850-LC
GB
Instruction Manual Battery-hydraulic Pump
authorised
copy
The battery-hydraulic pump is equipped with a controller enabling the user to see when the next service is due by
fl ashing for 20 sec. at the end of a working cycle. When the next service is due after 10.000 cycles the unit must
be returned to an authorised service center (ASC). Failure to observe this request results in loosing the Warranty.
Preventive maintenance serves your safety. Within the determined use of the tool only the batteries are permitted to
be changed by the customers.
Attention
Do not damage the seals of the tool
Attention
Have the power tool repaired by a qualifi ed expert or by a Klauke ASC before use.
It is advisable to have the pump serviced by a specialist during regular intervals to safeguard a technically proper
state before use.
Table 2 - Service schedule
What?
When?
Who?
Cleaning
after each use
Service personnel
Check oil level
weekly
Service personnel
Check high pressure hose
weekly
Specialist
Proper state
quarterly
Electric specialist
Change hydraulic oil
annually
Manufacturer/Specialist
The hydraulic oil has to be completely changed annually or after 10.000 working cycles.
We recommend to have the service done in specialised companies where the save disposal of the oil is guaranteed
for environmental protection.
Attention
Please use only clean, proper hydraulic oil. (Rivolta S.B.H. 11 and other hydraulic oils of similar quality)
Attention
Hydraulic oils can cause cutaneous eruption (eczema) or other health hazards. Avoid longer skin contact.
Wash your hands carefully after each contact.