Attention
Do not operate the pump without a working unit.
Attention
Before starting to operate the pump the oil level must be checked and possibly adjusted.
4. Besides the built-in trigger the following accessories can be connected:
• Remote control HTA4
• Safety foot switch incl. 4m cable FTA4
The pump recognises the various accessories through a special coding; the forward key will be deactivated accor-
dingly.
5. The battery and possibly the spare battery will be plugged into the sockets.
6. The pump is now ready to operate. The LCD display is activated.
7. Select the program for the intended application by turning the selection knob or the data function.
8. The working cycle is initiated by activating the advance function of the ‚forward and return keys‘
Attention
The crimping cycle can be stopped at any time by releasing or stepping down the actuator of the safety foot
switch, resp. releasing the two hand safety switch .
Once the three step safety foot switch has been stepped down, it can only be reactivated by pushing the reset button
of the foot switch. This reset button is located on the top of the foot switch.
Attention
After having terminated the working cycle and prior to changing the dies remove battery to avoid un-
intended use. Avoid unintended starts. Make sure the switch is in the off position before plugging in.
For transport turn the program selection switch to position 7 to avoid unintended starts.
3.2 Explanation of the application range
The battery hydraulic pump can be operated with all of the crimping heads in our catalogue.
Attention
Do not crimp on live cables or conductors.