915FS Splicer
Greenlee / A Textron Company
1390 Aspen Way • Vista, CA 92081 USA • 800-642-2155
16
Notes:
• Splice point sometimes looks a bit fatter than other parts. This is considered a
normal splice and does not affect splice loss.
• To change threshold for estimated splice loss or cleave angle, refer to “Splice
Mode” in this manual for details.
• Splice loss may be improved in some cases by additional arc discharges.
Press or
as displayed in the main splicing screen, for an additional arc
discharge (re-arc). Splice loss estimate and splice check are performed again.
Splice loss may be worsened in some cases by additional arc discharges
(re-arcs). Additional arc discharge can be set to “disabled”, or limited to the
number of additional arcs.
• Splicing result is automatically saved in splicer memory.
Heating Protection Sleeve
1. Transfer the fiber with protection sleeve from the centering device to the tube heater.
2. Close the tube heater lid.
Notes:
• Make sure the splice point is located at the center of the protection sleeve.
• Make sure the strength member in the protection sleeve is placed downward.
• Make sure the fiber is not distorted.
• The splice-on connector must be installed on the right-hand side of the splicer
heater. Use heater profile #1 for the SOC.
3. Press to start tube heating. The beeper sounds and the HEAT LED (red color)
turns off when tube heating is completed.
4. Open the tube heater lids and remove the protected fiber from the tube heater.
Apply some tension to the fiber while removing it from the tube heater.
5. Visually inspect the finished sleeve to verify that no bubbles or debris/dust is present
in the sleeve.