Common faults, root cause for these and suggested actions are provided in TABLE 2 below:
Fault
Possible causes
Suggested actions
Pump does not
run
No power supply
Check incoming power supply and rectify
Motor tripping by TOP
Allow the motor to cool
Very low voltage
Operate in the recommended voltage range
Pump is jammed
Dismantle the pump and clear the jammed parts
Capacitor failure
Change the capacitor
Loose connections
Check the connections
Pump has been kept idle for long
time
Ensure free rotation of shaft by running the pump
for few minutes at least every alternate day
Pump does
not discharge
water
Foot valve leakage
Change the faulty foot valve
Pump not primed
Prime the pump
Air leakage on the suction side
Check and correct for leakages
Foot valve exposed due to large
draw down / poor yield of bore
Lower the foot valve and ensure that the foot valve
is always submerged after draw down.
Wait for water level to rise before pumping
Low-voltage operation
Operate in the recommended voltage range
Pump shaft has sheared
Replace the assembly rotor
11. Basic troubleshooting
Warning
To prevent serious accidents, disconnect the power supply before
inspecting the pump.
OMJP001A
30
2020.01
Содержание Taro HCS SJ Series
Страница 1: ...Single Phase Jet Monoblocks Instruction Operating Manual OMJP001A 2020 01 ...
Страница 2: ...OMJP001A 2 2020 01 ...
Страница 24: ...BORE WELL JET UNIT FOOT VALVE DELIVERY PIPE JAR PRESSURE VALVE FILLING PLUG 8 e OMJP001A 24 2020 01 ...
Страница 33: ...OMJP001A 33 2020 01 ...
Страница 40: ...OMJP001A 40 2020 01 ...