Use a single power cable from the power source to the Single Phase Jet Monoblock. Do not use a
power cable with large number of joints as this can result in a significant voltage drop
During installation, ensure the Single Phase Jet Monoblock is not subject to shock loads which
can damage the pumpset parts
The Jet Pump can be installed either close to the well or away from it. The pipes from the Jet
Pump to the well must slope down
The Jet Unit should be located around 3m below the lowest water level in the well
Note
If you detect damage or discrepancy in the product, contact the dealer from
whom the pump was purchased
Warning
Do not use the Jet Pump for oil, toxic, corrosive and flammable liquids.
Pumping flammable liquids could cause explosion
Caution
Ensure suitable precautions are taken while lifting and lowering the product
Caution
Use trained professionals to install the Single Phase Jet Monoblock
Warning
Use a power supply cable that has sufficient rating. Factor in low-voltage
operation
Warning
Provide proper earthing. Improper earthing can cause electrical shock
Caution
Use a Megger to verify the insulation resistance of the motor. Insulation
resistance should be 20MΩ minimum
OMJP001A
17
2020.01