Texmate, Inc. Tel. (760) 598-9899  •  www.texmate.com

PM-35U Manual  (P1)

Page 3

described in the text.  

NOTE:  Use  of  these  application  circuits  is  entirely  at  the  risk  and 

responsibility of the user and any user modification of the meter may at 

the discretion of Texmate, void the warranty.  (See rear page for user's 

responsibility  and  warranty  details)    The  following  legend  applies  to 

all application circuits: 1) optional component positions are shown in 

dotted lines; 2) internal solder junctions are shown by         for a closed 

junction or         for an open junction; 3) calibration voltages as mea

-

sured by an external user supplied voltmeter are shown by

Typical Application Connections

The PM-35U may be used in a wide variety of configurations.  

The  following  circuits  illustrate  some  of  the  possibilities  and 

demonstrate  the  exceptional  versatility  of  Texmate  products.  

Components called for in the applications which are not part 

of the standard meter may be supplied by the user or in some 

cases purchased from Texmate.  The circuit diagrams explain 

the  basic  pinout  connections  required  for  each  application.  

Unless  otherwise  specified,  the  diagrams  will  show  the  com

-

ponent  values  and  solder  junctions  that  would  normally  be 

installed on a standard 2V range meter.  For those applications 

which  have  alternative  ranges  and/or  input  configurations, 

the  required  component  values  and  any  modifications  are 

  F.S. In 

Rs External 

Resolution

  20A 

0.01 

10mA

  2A 

0.1 

1mA

 

F.S. In 

Rs Internal 

Resolution

  200mA 

100µA

  20mA 

10 

10µA

  2mA 

100 

1µA

   200µA 

1k 

100nA

F.S. In  Rs+R

T

 Resolution

200 100  100m

2k 

1k 

1

20k 

10k 

10

200k 

100k 

100

2M 

1M 

1k

20M 

10M 

10k

F.S. In 

R1 

R2        Resolution

200mV  omit 

omit 

100µV

2V 

omit 

omit 

1mV

20V 9M 1M  10mV

200V 

10M 

100k 

100mV

1200V  10M 

10k 

1V

VOLTAGE RANGE CHANGE

CURRENT RANGE CHANGE (*)

Use 200mV F.S. meter for minimum voltage drop.

OHMMETER RANGE CHANGE

Useful Tables

DIFFERENTIAL METER - 200mV RANGE, 

>2V Range, or EXTERNAL REFERENCE

200mV Range : 1) Change R6 from 470k to 

47k, ±5%; 2) Change R9 from 18.2k to 26.7k, 

±1%; 3) Remove R8 (9.53k) and short with a 

jumper; 4) It is rec om mended that C4, C5 and 

C7 be changed to 0.22mF; 5) Adjust R10 until 

CV1= 100mV. 

>2V Range:  Install  R1  and  R2  as  specified 

under section titled Useful Tables.

External Reference: 1) Cut open solder junc

-

tion J1; 2) Con nect Pin E to Pin K;3) Connect 

moving arm of RB to Pin D.

SIMULTANEOUS VOLTAGE AND CURRENT 

MEAS URE MENT

1) Connect meter as for 200mV voltmeter for 

minimum drop on Rs or R2. Use Rs externally 

for currents greater than 200mA; 2) Install R1, 

R2,  and  Rs  as  specified  under  section  titled 

Useful Tables.  NOTE:  Rs  must  be  located  in 

low  side  of  the  current  loop  and  Signal  Low 

Input Pin J of voltmeter must not be grounded. 

If it is necessary to install Rs on the high side 

of the current loop, the ammeter must be op er-

at ed from an isolated power supply.

RATIOMETRIC VOLTMETER

Reading =(V1 ÷ V2) x 1000 where -2V ≤ V1 ≤ 

+2.8V  and +100mV ≤ V2 ≤ +4V and 0000 < 

Reading <1999. Cut open solder junction J1.

DIFFERENTIAL  RATIOMETRIC  OHM ME TER

1) Select RL so that the voltage drop across RL 

is not less than 3V for that range in F.S., or use 

a 3.9V Zener diode instead of RL; 2) Install RS 

and RT as specified under sec tion titled Useful 

Tables; 3) Cut open solder junction J1.

SINGLE-ENDED CURRENT METER

1)  Connect  meter  as  for  200mV  voltmeter; 

2)  Install  Rs. NOTE: Rs  must  be  externally 

mounted when current is greater than 200mA. 

Standard  values  for  Rs  are  speci fied  under 

section  titled  Useful  Tables.  For  all  other 

ranges, Rs may be internally mount ed in the 

R2 po si tion.

8

9

10

6

J

K

L

5VDC

-

+

F

+

-

CURRENT

SHUNT

RESISTOR Rs

R

2

Vo

R    LOAD

L

8

9

10

6

J

L

5VDC

-

+

F

R1

R2

7

H

E

4

Cv1

D

R10

2k

R9

18.2k

R8

9.53k

C4

C6

R6

470k

K

J1

-

+

+5V

+

-

Vo

C

C

R

R

R

R C

C V

1 2 V

+ V

. C V

-1.5V o +2.8V

R

R

R

R C

V

2V

V

2V

R

R

R

C

V

V

V

8

9

10

6

J

K

L

5VDC

-

+

F

4

E

CUT J1 

OPEN

D

3.9 V ZENER

R   (CURRENT LIMITING)

L

DEVICE

UNDER

TEST

Rx

Rs
STANDARD

R

T

8

9

10

6

J

K

L

5VDC

-

+

F

V1

4

E

V2

+

-

+

-

CUT J1 

OPEN

D

8

9

10

6

J

K

L

F

CURRENT

SHUNT

RESISTOR

Rs

R2

Vo

8

9

10

6
J

K

L

5VDC

-

+

F

R1

R2

R    

LOAD

L

AMMETER

7

+

-

VOLT

DO NOT GROUND THIS WIRE

VOLTMETER

H

MEASURE TEMPERATURE DIFFERENCE

Meter  Reading  =199.9˚C  Max.  where 

-50˚C≤(T1,  T2)<+150˚C.

5VDC POWER SUPPLY MONITOR

Install R1 and R2 with component 

values shown.

7VDC TO 20VDC POWER SUPPLY MONITOR

Install R1 and R2 with values shown.

8

F

9

10

6

J

K

L

820

820

T1

LM135

T2

LM135

5VDC

-

+

8

9

10

6
J

K

L

-

+

F

R1

R2

7

H

9M

1M

Ω

Ω

LM341P5V

7 ~ 20VDC

0.1   F

μ

8

9

10

6
J

K

L

5VDC

-

+

F

R1

R2

7

H

9M

1M