Options

4A

Order Code

OR12

OR14

-

4A

4A

4A

-

*R214

see note

SP2

SP4

SP1

SP3

9A

9A

9A

9A

9A

4A

4A

9A

SP3

SP1

SP4

SP2

Relay Modules with 2 Non-Isolated 4A Form A Relays,

and 2 Non-Isolated 9A Form C Relays

DL-40JANUS Series

Normally 

Open

Normally 

Close

29

28 27

25

26

24 23 22

Options

Order Code

OR52

OR54

-

-

210mA

210mA

210mA

210mA

210mA

210mA

SP4

SP3

SP2

SP1

SP4

SP3

SP2

SP1

Relay Modules with 4 Independent 400V

210mA DC only SSRs

DL-40JANUS Series

29

28 27

25

26

24 23 22

Options

Order Code

OR32

-

-

4A

4A

4A

4A

4A

4A

OR34

4A

4A

4A

4A

4A

4A

SP4

SP3

SP2

SP1

SP1

SP2

SP3

SP4

Relay Modules with 4 Isolated 4A Form A Relays

DL-40JANUS Series

*R234

see note

Normally 

Open

Connector Pinouts continued

On board Relay Pins 8 to 11 and Relay Output Module Pins 22 to 29  

Installation Guidelines

Installation 

 

   

1. Install and wire meter per local applicable codes/reg-

ulations, the particular application, and good installation 

practices.

2. Install meter in a location that does not exceed the 

maximum operating temperature and that provides 

good air circulation.

3. Separate input/output leads from power lines to 

protect the meter from external noise.  Input/output 

leads should be routed as far away as possible from 

contactors, control relays, transformers and other noisy 

components.  Shielding cables for input/output leads is 

recommended with shield connection to earth ground 

near the meter preferred.

4. A circuit breaker or disconnect switch is required to 

disconnect power to the meter.  The breaker/switch 

should be in close proximity to the meter and marked as 

the disconnecting device for the meter or meter circuit.  

The circuit breaker or wall switch must be rated for the 

applied voltage (e.g., 120VAC or 240VAC) and current 

appropriate for the electrical application (e.g., 15A or 

20A).

5. See 

Case Dimensions section

 for panel cutout infor-

mation.

6. See 

Connector Pinouts section

 for wiring.

7. Use 28-12 AWG wiring, minimum 90˚C (HH) tempera-

ture rating.  Strip wire approximately 0.3 in. (7-8 mm).

8. Recommended torque on all terminal plug screws is 

4.5 lb-in (0.51 N-m).

8

9

10 11

DL-40JANUS Series

SP2

SP1

Normally 

Open

Isolated On Board 4A Form A Relays

Order Code

R2

SP1

SP2

4A

4A

*Note: If relays for setpoints 1 & 2 (R2)

are installed on the main board, and 

a relay output module is used that 

also has relays in the setpoints 1 & 

2 (OR14 or OR34), the duplicate 

relays will operate in unison.

Содержание DL-40JANUS-SG

Страница 1: ...utput Range Setting and Calibration 6 General Features Specifications Software Features Index LEOPARD FAMILY DL 40JANUS SG Two scaling methods MANUAL no external sig nal source required and AUTO requi...

Страница 2: ...by pressing and releasing the or buttons When there are more than two display selec tions they are shown in brackets below the first display and are also selectable by press ing and releasing the or b...

Страница 3: ...L POINT AND BRIGHTNESS SELECTION See Page 6 Setpoint 3 SP3 Setpoint 4 SP4 Valley Offset Scale Factor Calibrate Analog Output Lo Calibrate Analog Output Hi X XXX XX XX XXX X XXXX XXXX 2 3 4 Decimal Poi...

Страница 4: ...t STEP B Select Between Calibration of Input or Output Note If the analog output option is not present Step B is skipped and the program goes directly from Step A to Step C 1 Press the or button to se...

Страница 5: ...Point Analog Output Note If the analog output option is not present Step B is skipped and the program goes directly from Step A to Step C 1 Press the or button to select the display toggling from CAL...

Страница 6: ...s the P and buttons at the same time Display toggles between CAL and oFF 2 Press the P button Display shows previous dP selection STEP E Set the Decimal Point 1 Using the and adjust the display to the...

Страница 7: ...unts and does not include the deci mal point If you need the decimal value with decimal point you will need to read the register convert it to decimal read 40024 see below to determine decimal locatio...

Страница 8: ...ST2 Setpoint 2 Hysteresis setting 40019 0x0012 SINT16 R W 1999 9999 PRES3 Setpoint 3 setting 40020 0x0013 UINT16 R W 0 9999 HYST3 Setpoint 3 Hysteresis setting 40021 0x0014 SINT16 R W 1999 9999 PRES4...

Страница 9: ...P2 Delay on Make doM Delay Time Setting STEP H Set the SP2 Delay on Break dob Delay Time Setting STEP I Set the Hysteresis Setting for Setpoint 2 1 Using the and buttons adjust the display to the desi...

Страница 10: ...with external signal OFF 17 16 19 19 18 MANUAL rescaling ON AUTO scaling OFF ON SP1 NO SP1 NO SP2 NO SP2 NO Pins 14 and 15 AC DC Power Input Auto sensing AC DC power supply For voltages between 85 265...

Страница 11: ...air circulation 3 Separate input output leads from power lines to protect the meter from external noise Input output leads should be routed as far away as possible from contactors control relays tran...

Страница 12: ...71 1 8 DIN Cutout spacers 87 4mm 3 45 Various bezel colors are available Black is standard Prog SP3 SP4 SP2 SP1 For additional strength extra Mounting Slide Clips can be ordered and doubled up one beh...

Страница 13: ...se is made from fire retardant polycar bonate A metal surround case can be ordered to enhance the meter s fire retardant capabilities and also provide shielding against electromagnetic interference EM...

Страница 14: ...OA____ DL 40JANUS SG Add to the basic model number the order code suffix for each standard option required The last suffix is to indicate how many different special options and or accessories that you...

Отзывы: