background image

Texmate, Inc. Tel. (760) 598-9899  •  www.texmate.com

DL-40JANUS-SG manual (d0116)

Page 13

Clear Lockable Water-proof Lens Cover OP-N4X/96X48

Metal Surround Case Option OP-MTL96X48

The clear lockable cover is designed to be dust 

and water proof to NEMA-4X, IP65 standards. The 

assembly consists of a base and cover with a cam 

hinge and key-lock fastening mechanism. An O-ring, 

or neoprene gasket forms a seal between the base 

and the panel. The cam hinge prevents the cover from 

closing when opened until pushed closed. The cover 

has a tapered recess that, when closed, forms a seal 

with a tapered spigot on the base. A key-lock employs 

a cam locking device to force the spigot into the 

recess, ensuring seal integrity. A safety catch keeps 

the cover closed even when the key is removed, and 

the keyhole can be used to attach a safety seal clip, 

preventing unauthorized opening.

The meter’s plastic case is made from fire retardant polycar-

bonate. A metal surround case can be ordered to enhance the 

meter’s  fire  retardant  capabilities  and  also  provide  shielding 

against electromagnetic interference (EMI). The metal case 

slides over the polycarbonate case and is held firmly in place by 

spring-type non-return clips. The Metal Surround Case must be 

factory installed on the polycarbonate case and once installed, 

it cannot be removed in the field.

With the metal case in place, the meter’s standard ratchet-type 

mounting clips can not be used. Instead a pair of screw-type 

DIN standard mounting clips are provided, which clip into holes 

on the side of the metal case and tighten against the rear of the 

panel. A ground tab on the metal case enables the metal case 

to be easily connected to the panel ground.  

Safety Catch

O-ring Gasket

Cover

Removable 

key-lock

Clear Lockable NEMA 4X Dust 

and Splash Proof Cover

PN: OP-N4/96x48

Ground

Tab

Metal Surround Case 

& Mounting Clips

Part No. 

OP-MTL96X48

Meter with 

Metal

 

Surround Case

 

and screw-type mounting clips 

assembled

Screw-type 

Mounting Clip

Содержание DL-40JANUS-SG

Страница 1: ...utput Range Setting and Calibration 6 General Features Specifications Software Features Index LEOPARD FAMILY DL 40JANUS SG Two scaling methods MANUAL no external sig nal source required and AUTO requi...

Страница 2: ...by pressing and releasing the or buttons When there are more than two display selec tions they are shown in brackets below the first display and are also selectable by press ing and releasing the or b...

Страница 3: ...L POINT AND BRIGHTNESS SELECTION See Page 6 Setpoint 3 SP3 Setpoint 4 SP4 Valley Offset Scale Factor Calibrate Analog Output Lo Calibrate Analog Output Hi X XXX XX XX XXX X XXXX XXXX 2 3 4 Decimal Poi...

Страница 4: ...t STEP B Select Between Calibration of Input or Output Note If the analog output option is not present Step B is skipped and the program goes directly from Step A to Step C 1 Press the or button to se...

Страница 5: ...Point Analog Output Note If the analog output option is not present Step B is skipped and the program goes directly from Step A to Step C 1 Press the or button to select the display toggling from CAL...

Страница 6: ...s the P and buttons at the same time Display toggles between CAL and oFF 2 Press the P button Display shows previous dP selection STEP E Set the Decimal Point 1 Using the and adjust the display to the...

Страница 7: ...unts and does not include the deci mal point If you need the decimal value with decimal point you will need to read the register convert it to decimal read 40024 see below to determine decimal locatio...

Страница 8: ...ST2 Setpoint 2 Hysteresis setting 40019 0x0012 SINT16 R W 1999 9999 PRES3 Setpoint 3 setting 40020 0x0013 UINT16 R W 0 9999 HYST3 Setpoint 3 Hysteresis setting 40021 0x0014 SINT16 R W 1999 9999 PRES4...

Страница 9: ...P2 Delay on Make doM Delay Time Setting STEP H Set the SP2 Delay on Break dob Delay Time Setting STEP I Set the Hysteresis Setting for Setpoint 2 1 Using the and buttons adjust the display to the desi...

Страница 10: ...with external signal OFF 17 16 19 19 18 MANUAL rescaling ON AUTO scaling OFF ON SP1 NO SP1 NO SP2 NO SP2 NO Pins 14 and 15 AC DC Power Input Auto sensing AC DC power supply For voltages between 85 265...

Страница 11: ...air circulation 3 Separate input output leads from power lines to protect the meter from external noise Input output leads should be routed as far away as possible from contactors control relays tran...

Страница 12: ...71 1 8 DIN Cutout spacers 87 4mm 3 45 Various bezel colors are available Black is standard Prog SP3 SP4 SP2 SP1 For additional strength extra Mounting Slide Clips can be ordered and doubled up one beh...

Страница 13: ...se is made from fire retardant polycar bonate A metal surround case can be ordered to enhance the meter s fire retardant capabilities and also provide shielding against electromagnetic interference EM...

Страница 14: ...OA____ DL 40JANUS SG Add to the basic model number the order code suffix for each standard option required The last suffix is to indicate how many different special options and or accessories that you...

Отзывы: