33
Table 5-2: SO logic selection
SW1-5 setting
SO signal level
J1-2(3), 15
Power supply
output
Display
Down (default)
2-15V or Open
0-0.6V or Short
On
Off
Voltage/Current
“SO”
Up
2-15V or Open
0-0.6V or Short
Off
On
“SO”
Voltage/Current
NOTE
This function cannot be used with Output OFF. Please turn ON an output using the function of output
interception (SO).
5.8.
ENABLE/DISABLE CONTROL VIA REAR PANEL J1 CONNECTOR
Contacts 1 and 14 of J1 (Fig.4-2, Item 5) serve as Output Enable/Disable terminals by switch or relay.
This function is enabled or disabled by the SW1 Setup switch position 9. Refer to Table 5-3 for
Enable/Disable function andSW1setting.
Table 5-3: Enable/Disable function and SW1 setting
SW1-9 setting Enable/Disable inputs Power supply output
Display
ALARM LED
Down (default)
Open or Short
On
Voltage/Current
Off
Open
Off
“ENA”
Blinking
Up
Short
On
Voltage/Current
Off
NOTE
If the Enable/Disable inputs are opened when the unit is in Safe Start
mode, it is required to short the Enable /Disable inputs and then press
OUTPUT button or send OUT 1 command to resume operation.
CAUTION
To prevent possible damage to the unit, do not connect any of the
Enable/Disable inputs to the positive or negative output potential
.
Содержание PU100-7.5
Страница 2: ......
Страница 10: ......
Страница 17: ...7...
Страница 74: ...1850 1 Tsuruma Machida shi Tokyo 194 0004 Japan http www texio jp...