Premier 412/816/832 Master User Manual
Operating the Alarm System
INS141-6
7
Cancelling the Arming Process
"
To cancel the arming process during the exit delay:
Premier 816
17:30.21 28/04
Armed
Zones
8
7
6
5
4
3
2
1
Ready
Alarm
Service
MENU for Options
NO to Disarm?
Arming has been cancelled and the alarm system is
now disarmed.
Press
d
Enter Access code
????
Armed
Zones
8
7
6
5
4
3
2
1
Ready
Alarm
Service
1
2
3
Press
n
"
If the system only has one partition you will not have
to perform step 2.
Disarming During Entry
"
To disarm the alarm system during entry, proceed as
follows:
Premier 816
08:31.12 28/04
Armed
Zones
8
7
6
5
4
3
2
1
Ready
Alarm
Service
Enter Your Code
08:30.59 28/04
The entry tone will stop and the
light will turn off.
The alarm system is now disarmed.
Armed
Enter Access code
????
Armed
Zones
8
7
6
5
4
3
2
1
Ready
Alarm
Service
1
2
3
Enter the premises via the designated entry point,
the entry tone will sound. Proceed directly to the
remote keypad.
"
If a valid Access code is not entered before the end of
the entry delay, an alarm will occur.
Disarming when not in Entry
"
To disarm the alarm system when not in entry, proceed
as follows:
Premier 816
17:30.21 28/04
Armed
Zones
8
7
6
5
4
3
2
1
Ready
Alarm
Service
MENU for Options
NO to Disarm?
The
light will turn off. The alarm system is now
disarmed.
Armed
Press
d
Enter Access code
????
1
2
3
Press
n
Armed
Zones
8
7
6
5
4
3
2
1
Ready
Alarm
Service
"
If the system only has one partition you will not have
to perform step 2.
If the Quick Disarm feature is enabled and the system
is Stay armed you can omit step 1 from the above
procedure.
Disarming after an Alarm
"
To disarm the alarm system after an alarm, proceed as
follows:
Zone 05 Active
Master Bedroom
Master Bedroom
1... 21:10.56 28
The system is disarmed and the keypads display the
source of the alarm.
Enter Access code
????
1
2
Armed
Zones
8
7
6
5
4
3
2
1
Ready
Alarm
Service
The system must now be reset before you can arm again,
see page 11 for details on resetting alarms.
Auto Stay Arming
If your installer has enabled the Auto Stay feature the system
will automatically Stay arm if the entry/exit zone (front door)
is not activated whilst attempting to Away arm the system.
"
To auto Stay arm your alarm system proceed as follows:
Please Exit....
17:30.21 28/04
YES to Arm?
MENU for Options
The
light will flash and the exit tone will sound.
Armed
Press
a
Enter Access code
????
Press
y
Armed
Zones
8
7
6
5
4
3
2
1
Ready
Alarm
Service
1
2
3
Armed
Zones
8
7
6
5
4
3
2
1
Ready
Alarm
Service
Do NOT leave the premises during the exit delay. At
the end of the exit delay the alarm system will Stay arm.
Changing between Delayed and Instant Stay
When Stay arming the system the delayed zones (front door
etc) are normally delayed, i.e., when a delayed zone is
violated it will start the entry delay timer. However, it is
possible to change the delayed zones to instant when the
system is in a Stay armed mode. If a delayed zone is
violated when the system is in the “Instant Stay” mode the
system will generate an alarm immediately.
"
To change from Delayed Stay to Instant Stay, proceed
as follows:
INSTANT STAY
17:30.21 28/04
The
light will flash quickly.
The system is
armed.
Armed
Instant Stay
Press and hold the
key until you hear the
confirmation tone.
s
1
2
3
Ensure that the system is
armed.
Stay
Armed
Zones
8
7
6
5
4
3
2
1
Ready
Alarm
Service
"
If the system is fitted with a Premier RKP8/16 Plus the