![Texecom Premier 412 Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/texecom/premier-412/premier-412_master-user-manual_1097232006.webp)
Operating the Alarm System
Premier 412/816/832 Master User Manual
6
INS141-6
2.
Operating the Alarm System
Introduction
Before attempting to operate the alarm system ensure you
have familiarised yourself with all the arming and disarming
methods covered in this section.
Access Codes
•
If you make a mistake whilst entering your Access code,
simply enter the correct Access code.
Arming & Disarming the Alarm System
Checking if the System is Ready to Arm
To help prevent faults during arming, a Ready light has
been provided on each keypad. The Ready light works as
follows:
•
If the Ready light is on steady then the alarm system is
ready to be armed.
•
If the Ready light is flashing then the alarm system has
bypassed zones and/or Force Armable zones that are
violated, check these zones before proceeding.
•
If the Ready light is off then one or more zones are
violated, either secure or bypass these zones before
proceeding. The keypads will display the zones that are
violated:
Zone 04 Active
Patio Doors
Armed
Zones
8
7
6
5
4
3
2
1
Ready
Alarm
Service
Zone 01 Active
Front Door
Active zones are scrolled
in sequence on LCD keypads
Active zones are indicated by
the relevant zone lights on
LED Keypads
"
If any unbypassed zones that are not enabled for
“Force Arming” are violated at the end of the exit
delay this is termed an exit error and the alarm system
will go into fail set state (internal alarm). If
programmed by the installer the external bell will also
sound. Enter a valid user Access code to silence this
alarm.
A zone will only be armed when ALL associated
partitions are armed but will be disarmed when ANY
associated partition is disarmed.
Away Arming
The Away arming mode is normally used when leaving the
premises. When the system is armed in this mode all
detection zones assigned to your partition(s) will be armed.
The Ready light must be on steady before the alarm system
can be Away armed.
"
To Away arm the alarm system proceed as follows:
Please Exit....
17:30.21 28/04
YES to Arm?
MENU for Options
The
light will flash and the exit tone will sound.
Armed
Press
a
Enter Access code
????
Press
y
Armed
Zones
8
7
6
5
4
3
2
1
Ready
Alarm
Service
1
2
3
Armed
Zones
8
7
6
5
4
3
2
1
Ready
Alarm
Service
Leave the premises, when the system has armed the
exit tone will stop. The system is now Away armed.
"
If the Quick Arm feature is enabled, you can omit step
1 from the above procedure.
Stay Arming
The Stay arming mode is normally used when the premises
will be occupied. When the system is armed in this mode all
Interior detection zones assigned to your partition(s) will be
bypassed. Before Stay arming check the following:
•
Secure or bypass any perimeter zones that are violated.
•
Ensure no perimeter zones are bypassed
unintentionally.
•
Ensure no perimeter Force Armable zones are violated
unintentionally.
"
To Stay arm the alarm system proceed as follows:
Premier 816
17:30.21 28/04
YES to Arm?
MENU for Options
The alarm system will arm immediately and the
light will flash.
Armed
Press
s
Enter Access code
????
Armed
Zones
8
7
6
5
4
3
2
1
Ready
Alarm
Service
1
2
3
Armed
Zones
8
7
6
5
4
3
2
1
Ready
Alarm
Service
The system is now Stay armed.
"
If the Quick Arm feature is enabled, you can omit step
1 from the above procedure.
If the system is fitted with a Premier RKP8/16 Plus then
the Stay light will also illuminate when the system is
Stay armed.