Technical Specification

Sounder

Maximum Sounder Output (dBA @ 1m)

118

Strobe Frequency (Hz)

1

Input Voltage

- Maximum

15

- Minimum

10

Current Consumption (mA) @ 13.2V

- Sounder (SAB mode)

320

- Sounder (SCB mode)

40

- Strobe

120

- Standby Current

35

- Maximum battery charge current 

20

(constant current charger)

Содержание Flashguard

Страница 1: ...lation 42 103460 6 GB E Texecom Ltd St Crispin Way Haslingden Lancashire BB4 4PW Technical Helpline 08456 300 600 Sales Hotline 01706 220460 Fax 01706 223450 Email Sales texe com Project Advanced Secu...

Страница 2: ...Premier Alarm Sounder Backplates Flashguard The Installer s Choice GB 1 5 Installation Instructions E 6 10 Instrucciones de Instalaci n...

Страница 3: ...7 STROBE VE TRIGGER VE TRIGGER VE STROBE VE SUPPLY VE SUPPLY VE TAMPER RETURN TAMPER SERIES MICRO B MOCRO A 0 1 2 3 4 5 6 7 8 9 10 11 KLAXON SIGNALS LTD 42 103588 VER A 2004 G H K L I In ns st ta al l...

Страница 4: ...tomatic 5 second sound test The LED s will not illuminate until the hold off voltage is applied SAB SCB Operation E Move the jumper to SCB position to minimise the current drawn from the control panel...

Страница 5: ...upply OV Hold Off Supply Tamper Return 3 GB For use with positively triggered panels only Do not connect to Supply 12V Hold Off when using a standard negatively triggered panel Applying a negative vol...

Страница 6: ...sure battery leads are connected to correct polarity terminals Note The strobe circuit can retain a stored charge for some time after the power to the circuit has been removed Care should be taken whe...

Страница 7: ...220460 Technical Specification Sounder Maximum Sounder Output dBA 1m 118 Strobe Frequency Hz 1 Input Voltage Maximum 15 Minimum 10 Current Consumption mA 13 2V Sounder SAB mode 320 Sounder SCB mode 4...

Страница 8: ...LOW FAST J2 J1 T1 M4 M3 CON3 R4 C2 C1 C6 L1 C7 T2 X1 D7 STROBE VE TRIGGER VE TRIGGER VE STROBE VE SUPPLY VE SUPPLY VE TAMPER RETURN TAMPER SERIES MICRO B MOCRO A 0 1 2 3 4 5 6 7 8 9 10 11 KLAXON SIGNA...

Страница 9: ...descritos en la secci n 2 Cierre y asegure el tornillo 2 Configuraci n de Puente Bater a BATT F Una vez instalado este puente debe moverse a la posici n ON para conectar la bater a Esto activar la pr...

Страница 10: ...Comenzar 12V Hold Off Fuente OV Hold Off Fuente Soborno regreso Para uso con centrales que tienen salidas positivo No lo conecte a la red 12V Hold Off si usa una central con salidas negativo La sirena...

Страница 11: ...l rev s Aseg rese que la polaridad sea la correcta Nota El circuito de Flash puede retener carga el ctrica por mucho tiempo despu s de haberse desconectado Debe tenerse mucho cuidado al manejar este P...

Страница 12: ...n Tecnica Potencia Maxima De Sonido dBA 1m 118 Frequencia De Flash Hz 1 VOLTAGE MAXIMO Maximo 15 Minimo 10 Consumo de Corriente mA 13 2V Sirena Modo SAB 320 Sirena Modo SCB 40 Flash 120 Corriente En R...

Отзывы: