To link a LUN to the selected controller, select “Link LUN(s) to
controller”.
•
From the sub-menu that lists all LUN numbers not already
linked to another FC port, select a LUN number and press
[ENTER].
If all LUNs are already linked to ports, then the system displays an
error message.
•
Select “Exit to the LUN configuration menu”
•
To save the changes once you have completed all LUN
configuration, select “Save changes and exit”
Unlinking Fibre Channel Ports from LUN
To unlink a LUN from an FC port:
•
From the Telnet Main Menu, select “LUN Setup”
•
Select “Link/unlink fibre channel controller(s) to/from
LUN(s)”
•
Select appropriate port (See Linking Fibre Channel Ports,
above)
•
Select “Unlink LUN(s) from controller”
•
A sub-menu appears, as shown in Figure 6-6: Unlink LUNs
Option, which provides a list of all LUNs that are linked to the
controller.
•
To unlink a LUN or all linked LUNs, select the LUN and press
[ENTER].
•
Select “Exit to the LUN configuration menu”
•
To save the changes once you have completed all LUN
configuration, select “Save changes and exit”
Figure 6-6: Unlink LUNs Option
RamSan-120
User’s Manual
- 62 -