Test Summary
8
SLUUC86 – March 2020
Copyright © 2020, Texas Instruments Incorporated
Using the UCC5304EVM-035
4.2.6
Bench Setup Diagram
The current bench setup diagram includes the function generator and oscilloscope connections.
Follow this connection procedure,
can be used as a reference.
1. Ensure the output of the function generator and voltage sources are disabled before connection.
2. Connect the function generator channel 1 to TP4 (IN) and TP8 (GND), see
3. Power supply 1: Connect the positive lead to the current meter input of DMM1, and connect the current
meter output of DMM1 to TP12 (VCCI), and negative node applied to TP16 (GND).
4. Power supply 2: Connect the positive lead to the current meter input of DMM2, and connect the current
meter output of DMM2 to TP7 (VDD), and negative node directly to TP15 (VSS).
5. Oscilloscope Ch-1: If a TPP1000 or other ground spring compatible probe is available, attach
oscilloscope channel-1 probe to TP3. Otherwise, connect positive node to TP9 (OUT) and TP13 (VSS).
Figure 2. Bench Setup Diagram and Configuration