Test Summary
6
SLUUC86 – March 2020
Copyright © 2020, Texas Instruments Incorporated
Using the UCC5304EVM-035
4
Test Summary
In this section, the default factory configuration for the jumper settings must be confirmed with the
reference image in
. Different jumper settings, PWM signal input options, and voltage source
settings are described in
and
4.1
Equipment
4.1.1
Power Supplies
Two DC power supplies with voltage/current above 18 V and 1 A, respectively are required, for example:
Agilent E3634A.
4.1.2
Function Generators
One 2-channel function generator over 200 kHz is required, for example: Tektronix AFG3252.
4.2
Equipment Setup
4.2.1
DC Power Supply Settings
•
DC power supply 1
–
Voltage setting: 5 V
–
Current limit: 0.100 A
•
DC power supply 2
–
Voltage setting: 12 V
–
Current limit: 0.100 A
4.2.2
Digital Multi-Meter (DMM) Settings
•
Digital multi-meter 1:
–
DC current measurement, auto-range.
•
Digital multi-meter 2:
–
DC current measurement, auto-range.