Texas Instruments UCC5304EVM-035 Скачать руководство пользователя страница 16

STANDARD TERMS FOR EVALUATION MODULES

1.

Delivery:

TI delivers TI evaluation boards, kits, or modules, including any accompanying demonstration software, components, and/or

documentation which may be provided together or separately (collectively, an “EVM” or “EVMs”) to the User (“User”) in accordance
with the terms set forth herein. User's acceptance of the EVM is expressly subject to the following terms.

1.1

EVMs are intended solely for product or software developers for use in a research and development setting to facilitate feasibility
evaluation, experimentation, or scientific analysis of TI semiconductors products. EVMs have no direct function and are not
finished products. EVMs shall not be directly or indirectly assembled as a part or subassembly in any finished product. For
clarification, any software or software tools provided with the EVM (“Software”) shall not be subject to the terms and conditions
set forth herein but rather shall be subject to the applicable terms that accompany such Software

1.2

EVMs are not intended for consumer or household use. EVMs may not be sold, sublicensed, leased, rented, loaned, assigned,
or otherwise distributed for commercial purposes by Users, in whole or in part, or used in any finished product or production
system.

2

Limited Warranty and Related Remedies/Disclaimers

:

2.1

These terms do not apply to Software. The warranty, if any, for Software is covered in the applicable Software License
Agreement.

2.2

TI warrants that the TI EVM will conform to TI's published specifications for ninety (90) days after the date TI delivers such EVM
to User. Notwithstanding the foregoing, TI shall not be liable for a nonconforming EVM if (a) the nonconformity was caused by
neglect, misuse or mistreatment by an entity other than TI, including improper installation or testing, or for any EVMs that have
been altered or modified in any way by an entity other than TI, (b) the nonconformity resulted from User's design, specifications
or instructions for such EVMs or improper system design, or (c) User has not paid on time. Testing and other quality control
techniques

are

used

to

the

extent

TI

deems

necessary.

TI

does

not

test

all

parameters

of

each

EVM.

User's claims against TI under this Section 2 are void if User fails to notify TI of any apparent defects in the EVMs within ten (10)
business days after delivery, or of any hidden defects with ten (10) business days after the defect has been detected.

2.3

TI's sole liability shall be at its option to repair or replace EVMs that fail to conform to the warranty set forth above, or credit
User's account for such EVM. TI's liability under this warranty shall be limited to EVMs that are returned during the warranty
period to the address designated by TI and that are determined by TI not to conform to such warranty. If TI elects to repair or
replace such EVM, TI shall have a reasonable time to repair such EVM or provide replacements. Repaired EVMs shall be
warranted for the remainder of the original warranty period. Replaced EVMs shall be warranted for a new full ninety (90) day
warranty period.

WARNING

Evaluation Kits are intended solely for use by technically qualified,

professional electronics experts who are familiar with the dangers

and application risks associated with handling electrical mechanical

components, systems, and subsystems.

User shall operate the Evaluation Kit within TI’s recommended

guidelines and any applicable legal or environmental requirements

as well as reasonable and customary safeguards. Failure to set up

and/or operate the Evaluation Kit within TI’s recommended

guidelines may result in personal injury or death or property

damage. Proper set up entails following TI’s instructions for

electrical ratings of interface circuits such as input, output and

electrical loads.

NOTE:

EXPOSURE TO ELECTROSTATIC DISCHARGE (ESD) MAY CAUSE DEGREDATION OR FAILURE OF THE EVALUATION
KIT; TI RECOMMENDS STORAGE OF THE EVALUATION KIT IN A PROTECTIVE ESD BAG.

Содержание UCC5304EVM-035

Страница 1: ...t Diagrams 13 8 List of Materials 15 List of Figures 1 Jumpers Installation Position 7 2 Bench Setup Diagram and Configuration 8 3 Example Input and Output Waveforms Inputs CH2 Outputs CH3 9 4 Example...

Страница 2: ...n mode transient immunity CMTI greater than 100 V ns The device has an impressive propagation delay of 28 ns and the tightest part to part delay matching in the industry of less than 5 ns which enable...

Страница 3: ...ed with minimized loop area in both the gate driver and power supply loops with bypassing capacitors For detailed device information see the UCC5304 4 A 6 A 5 7 kVRMS Isolated Single Channel Reinforce...

Страница 4: ...asured before gate drive resistor TP3 OUT_CAP Output measured at output capacitor TP4 IN Positive input TP5 VDD Output supply positive input TP6 IN Positive input TP7 VDD Output supply positive input...

Страница 5: ...not installed IN provided by external signal and this pin is low by default if left open Option A Option B Jumper on J1 2 and J1 1 sets IN low Option C Jumper on J1 2 and J1 3 sets IN high 3 Electrica...

Страница 6: ...d Section 3 4 1 Equipment 4 1 1 Power Supplies Two DC power supplies with voltage current above 18 V and 1 A respectively are required for example Agilent E3634A 4 1 2 Function Generators One 2 channe...

Страница 7: ...rator Settings Mode Frequency Duty Delay High Low Output Impedance Channel 1 Pulse 200 kHz 50 0 s 3 3 V 0 V High Z 4 2 4 Oscilloscope Setting Table 5 lists the oscilloscope setting Table 5 Oscilloscop...

Страница 8: ...function generator channel 1 to TP4 IN and TP8 GND see Figure 2 3 Power supply 1 Connect the positive lead to the current meter input of DMM1 and connect the current meter output of DMM1 to TP12 VCCI...

Страница 9: ...DMM1 should be approximately 1mA to 2mA 3 Enable power supply 2 The quiescent current on DMM2 should be approximately 0 75 mA to 2 mA if everything is set correctly 4 Enable the function generator out...

Страница 10: ...2020 Submit Documentation Feedback Copyright 2020 Texas Instruments Incorporated Using the UCC5304EVM 035 Figure 4 shows a zoomed in view of the example input and output waveforms Figure 4 Example Inp...

Страница 11: ...EVM 035 Figure 5 shows a zoomed in view of the example input and output waveforms Figure 5 Example Input and Output Waveforms Zoom In on Fall Input Ch2 Output Ch3 5 2 Power Down The following list des...

Страница 12: ...Schematic www ti com 12 SLUUC86 March 2020 Submit Documentation Feedback Copyright 2020 Texas Instruments Incorporated Using the UCC5304EVM 035 6 Schematic Figure 6 UCC5304EVM 035 Schematic...

Страница 13: ...ti com Layout Diagrams 13 SLUUC86 March 2020 Submit Documentation Feedback Copyright 2020 Texas Instruments Incorporated Using the UCC5304EVM 035 7 Layout Diagrams Figure 7 Top Overlay Figure 8 Top La...

Страница 14: ...Layout Diagrams www ti com 14 SLUUC86 March 2020 Submit Documentation Feedback Copyright 2020 Texas Instruments Incorporated Using the UCC5304EVM 035 Figure 9 Bottom Layer Figure 10 Bottom Overlay...

Страница 15: ...1 F 50 V 10 X7R 0805 1 C4 Capacitor ceramic 1800 pF 50 V 10 X7R 1206 1 C6 Capacitor ceramic 0 1 F 25 V 10 X7R 0603 1 D1 Diode Schottky 30 V 1 A MicroSMP 1 J1 Header 2 54 mm 3x1 Tin TH 1 R1 Resistor 1...

Страница 16: ...ther than TI b the nonconformity resulted from User s design specifications or instructions for such EVMs or improper system design or c User has not paid on time Testing and other quality control tec...

Страница 17: ...These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not in...

Страница 18: ...instructions set forth by Radio Law of Japan which includes but is not limited to the instructions below with respect to EVMs which for the avoidance of doubt are stated strictly for convenience and s...

Страница 19: ...any interfaces electronic and or mechanical between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents to minimize the risk of electr...

Страница 20: ...R DAMAGES ARE CLAIMED THE EXISTENCE OF MORE THAN ONE CLAIM SHALL NOT ENLARGE OR EXTEND THIS LIMIT 9 Return Policy Except as otherwise provided TI does not offer any refunds returns or exchanges Furthe...

Страница 21: ...e resources are subject to change without notice TI grants you permission to use these resources only for development of an application that uses the TI products described in the resource Other reprod...

Отзывы: