7.2 Recommended Test Setup
is the recommended test set up to evaluate the TPS51113-EVM. Working at an ESD workstation,
make sure that any wrist straps, bootstraps, or mats are connected referencing the user to earth ground before
power is applied to the EVM.
EXAS
T
I
NSTRUMENTS
FAN
V1
A1
DC
source
+
-
Load
-
+
V2
-
+
-
-
+
+
Figure 7-2. TPS51113-EVM Recommended Test Setup
7.2.1 Input Connections
1. Prior to connecting the DC input source V
IN
, it is advisable to limit the source current from V
IN
to 10 A
maximum. Make sure V
IN
is initially set to 0 V and connected as shown in
2. Connect a voltmeter V1 at TP1(V
IN
) and TP2 (GND) to measure the input voltage.
7.2.2 Output Connections
1. Connect Load to J2 and set Load to constant resistance mode to sink 0 A
DC
before V
IN
is applied.
2. Connect a voltmeter V2 at TP6 (V
OUT
) and TP8 (GND) to measure the output voltage.
7.2.3 Other Connections
Place a fan as shown in
and turn it on, making sure air is flowing across the EVM.
Test Setup
SLUU359A – APRIL 2009 – REVISED FEBRUARY 2022
TPS51113 Buck Controller Evaluation Module User's Guide
5