background image

ELECTRICAL THRUSTERS

*EN - 

INSTALLATION AND USER’S MANUAL

*Other languages available by scanning the QR code on the 

back of this manual or on the label on the product.

REV 002A

BTAC 

Series

BTAC 

250 200

BTAC 

300 300 - 300 350

BTAC 

386 420 - 386 450 

BTAC 

386 450HD - 386 520HD -

 

386 550HD - 386 620HD 

BTAC 

513 750 - 513 900 - 513 1000

BTAC 

610 1200 - 610 1400

Содержание BTAC Series

Страница 1: ...es available by scanning the QR code on the back of this manual or on the label on the product REV 002A BTAC Series BTAC 250 200 BTAC 300 300 300 350 BTAC 386 420 386 450 BTAC 386 450HD 386 520HD 386...

Страница 2: ......

Страница 3: ...allazione 8 4 0 Eliche 8 4 1 Tunnel 9 4 2 Thruster 10 4 1 Gearleg and motor support flange 250 300 11 4 2 Gearleg and motor support flange 386 12 4 3 Gearleg and motor support flange 513 610 12 4 3 Ri...

Страница 4: ......

Страница 5: ...nel 386 mm 15 13 64 Motor type Electric 2 poles Electric 4 poles Motor power 30 kW 30 kW 30 kW Voltage 400 690 V 400 690 V 400 690 V Thrust 420 kgf 925 lbf 450 kgf 992 lbf Tunnel thickness limit value...

Страница 6: ...w mill 120 mm 4 23 32 Male hex wrenches 4mm 6mm 5 mm 8 mm e 14 mm Fork or polygonal wrench 27 mm BTAC 513 Drill and drill bits 18 mm 45 64 Hollow mill 140 mm 5 33 64 Male hex wrenches 5 mm 8 mm e 14 m...

Страница 7: ...ctric motor near easily inflammable objects The terminals must be properly tightened Secure hold the inner nut when tightening MINIMUM TIGHTENING TORQUE IS 11 Nm 3 2 Precautions for the installer CARR...

Страница 8: ...The lever effect in the boat is proportional to the increase of the distance L1 and L2 between the barycentre and the position of the tunnel A and B FIG 3 For greater lever effect prefer position B F...

Страница 9: ...ear face of the tunnel which is an area exposed frontally to the water flow To limit this phenomenon prepare an indentation in the rear part of the tunnel The indentation will depend on the shape of t...

Страница 10: ...way point FIG 5 Use the flange to mark the centre of the holes on the tube FIG 4 FIG 5 1 0 2 3 4 5 6 7 8 9 10 FIG 6 Fix the drilling template on the reference points making sure they are aligned with...

Страница 11: ...l use around the point of contact between flange and tube Fasten everything to the flange using the special screws and washers SILICONE FIG 2 Grease the terminal part of the gearleg shaft fit the smal...

Страница 12: ...the terminal part of the gearleg shaft fit the small key into its seat FIG 1 FIG 2 SILICONE 4 3 Gearleg and motor support flange 513 610 FIG 1 FIG 2 FIG 3 SILICONE FIG 1 Fit the gearbox with the speci...

Страница 13: ...hten the fitting provided FIG 3 Insert the Rilsan hose onto the fitting and the tank BTAC 386 B00 FIG 1 FIG 2 FIG 3 BTAC 386 C00 FIG 1 FIG 2 FIG 3 BTAC 513 610 FIG 1 After fastening the flange turn th...

Страница 14: ...ine by at least 20 of the distance between the waterline and the centre of the tunnel distance d This is to ensure sufficient oil overpressure Fill the oil tank with gear oil type GL 5 0 2 x d WATERLI...

Страница 15: ...d the cush drive damper into the end of the gearleg shaft NOTE On the BTAC 386HD C00 tighten the set screw of the lower joint BTAC 386 B00 BTAC 386HD C00 BTAC 513 610 FIG 3 Grease the terminal part of...

Страница 16: ...ox by engaging them to the drive keys A secure the propellers with the self locking nuts D and set screws E only for BTAC 513 610 Secure the anodes F with screws G previously smeared with structural a...

Страница 17: ...TAC386420 30 kW 400 V 37 kW 33 kW BTAC386450 30 kW 400 V 37 kW 35 kW BTAC386450HD 30 kW 400 V 37 kW 35 kW BTAC386520HD 37 kW 400 V 37 kW 40 kW BTAC386550HD 37 kW 400 V 37 kW 40 kW BTAC386620HD 45 kW 4...

Страница 18: ...trongly forbidden to bypass or modify such protections in order to increase the operating time span lest voiding the warranty and thus lifting any responsibility from Quick SPA Make sure no swimmers o...

Страница 19: ...the anodes the sealings and the gearleg s shaft where the propellers are lodged Dismantle once a year following the points below Clean propellers tunnel and gearleg Replace the anodes carry out this o...

Страница 20: ...ided for by local regulations for this product category Some parts of the product may contain pollutants or hazardous substances that if dispersed may be harmful to the environment and human health As...

Страница 21: ...JOINT KIT BTAC 250 MOTOR FVSGG250AC00A00 2 OSP FLANGE FOR PROPELLER KIT BT 250 FVSGFLBTQ250A00 3 OSP GEARLEG KIT BT 250 FVSGGBBT2500A00 4 OSP PROPELLER KIT D250 RH FVSGEL250R00A00 5 OSP PROPELLER KIT...

Страница 22: ...TAC 300 MOTOR 15kW FVSGG300AC00A00 1B OSP JOINT KIT BTAC 300 MOTOR AC 22kW FVSGG300AC22A00 2 OSP PROPELLER FLANGE KIT BT 300 FVSGFLBTQ300A00 3 OSP GEARLEG KIT BT 300 FVSGGBBT3000A00 4 OSP PROPELLER KI...

Страница 23: ...B00 FVSGGBBT3860B00 4 OSP KIT ANODES FOR PROPELLER 386 FVSGANBTQ38AA00 5 OSP PROPELLER KIT 386R NYLON COMPLETE FVSGEL386R3PA00 6 OSP PROPELLER KIT 386L NYLON COMPLETE FVSGEL386L3PA00 7 OSP KIT GASKET...

Страница 24: ...MOTOR 45KW FVSGG3863260C00 2 OSP CUSH DRIVE DAMPER KIT D109 BT 386 FVSGGPVP1090A00 3 OSP GEARLEG KIT BT 386 R2 FVSGGBBT3862A00 4 OSP GASKET KIT BT 386 R2 FVSGGRBT3862A00 5 OSP PROPELLER KIT D386L P740...

Страница 25: ...FVSGG513900AC00 1C OSP JOINT KIT BTAC 513 1000 FVSGG513100AC00 2 OSP CUSH DRIVE DAMPER KIT 513 FVSGGPVP1200A00 3 OSP GEARLEG KIT BT 513 FVSGGBBT5130A00 4 OSP ANODES FOR PROPELLER KIT BT 513 AL FVSGAN...

Страница 26: ...GP61000AC00 2 OSP CUSH DRIVE DAMPER KIT D160 BT 610 FVSGGPVP1600A00 3 OSP GEARLEG KIT BT 610 FVSGGBBT6100A00 4 OSP ANODES FOR PROPELLER KIT BT 610 ALL FVSGANBTQ61AA00 5 OSP PROPELLER KIT RH D610 NIBRA...

Страница 27: ...B 386 15 13 64 C 508 20 BTAC 386 HD BTAC 386 30kW BTAC 386 37kW BTAC 386 45kW A 860 33 55 64 902 35 33 64 927 36 1 2 B 386 15 13 64 386 15 13 64 386 15 13 64 C 566 22 19 64 566 22 19 64 566 22 19 64...

Страница 28: ...QUICK BTAC SERIES INSTALLATION AND USER S MANUAL REV002A 28 Notes BTAC Series EN...

Страница 29: ...QUICK BTAC SERIES INSTALLATION AND USER S MANUAL REV002A 29 Notes BTAC Series EN...

Страница 30: ...ne RAVENNA ITALY Tel 39 0544 415061 Fax 39 0544 415047 www quickitaly com quick quickitaly com REV 002A BTAC Series BTAC 250 200 BTAC 300 300 300 350 BTAC 386 420 386 450 BTAC 386 450HD 386 520HD 386...

Отзывы: