4 - Installation
4.5 -
Positioning of coupling and oil tank
• Install the oil tank (1) above the waterline by at least 20% of the distance between the waterline and the centre of the tunnel
(distance d). This is to ensure sufficient oil overpressure.
• Fill the oil tank with gear oil type GL-5.
> 0,2 x d
WATERLINE
TUNNEL CENTRE
d
1
ARIA
OLIO
POSITION THE TUBE CORRECTLY IN ORDER TO AVOID A “SIPHON” EFFECT.
THE TANK MUST ALWAYS BE IN A VERTICAL POSITION.