Setup By Mode
9
SLAU754A – January 2018 – Revised August 2019
Copyright © 2018–2019, Texas Instruments Incorporated
TPA3220 Evaluation Module
Table 2. Jumper and Switch Configurations (PBTL Mode)
Component
Component Description
Configuration for PBTL
J23
Gain/SLV Select
MSTR-18dB
J24
N/A
IN
J4, J12
Input DIFF or SE Select
OUT = DIFF IN, IN = DIFF IN
J10, J11, J20, J21
AIB Input Select
Position 1:2 for RCA/XLR,
Position 2:3 for AIB
J6
HEAD or AD Mode Select
IN
J7, J8
PBTL or BTL Select
IN
J22
VDD SEL
Position 2:3 (GVDD)
J25
5V-PU SEL
OUT
S1
RESET Control
RESET
S2
MUTE Control
MUTE
J13
AUTO RETRY
OUT
J29
PVDD-IN
IN
J26
12V-IN
IN
J5
5V-IN
IN
J27
3.3V-IN
IN
J19
5V-PU EN
OUT
J17
OSC Output
No Connection
J16
Master or Slave Select
Position 3:4 MASTER MODE
2.2.2
Power-Up
Ensure that required connections and configurations have been checked. The TPA3220EVM board can
now be powered on.
1. Enable the power supply from 12 V to 30 V and ensure that LED D5 illuminates. LEDs D2 and D4
should not be illuminated.
2. Bring the EVM out of RESET state by switching RESET (S1) to NORMAL. You should see the FAULT
LED (D4) blink once quickly, then remain unilluminated.
3. Bring the EVM out of MUTE state by switching MUTE (S2) to NORMAL.
4. Note that the EVM does not have volume control, configure your analog input for a reasonable audio
level before beginning audio playback.
5. Enable audio input playback and the EVM should begin driving audio out of the left and right speakers.
If resistor loads are used for testing instead of speakers, they will now be energized.