![Texas Instruments TMS320F28004 Series Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/texas-instruments/tms320f28004-series/tms320f28004-series_manual_1095599012.webp)
Advisory
(continued)
FPU: FPU-to-CPU Register Move Operation Preceded by Any FPU 2p Operation
Instruction
F1
F2
D1
D2
R1
R2
E
W
R1
R2
E1
E2
E3
MPYF32 R6H, R5H, R0H
|| MOV32 *XAR7++, R4H
I2
F32TOUI16R R3H, R4H
I2
I1
ADDF32 R3H, R2H, R0H
|| MOV32 *--SP, R2H
I4
NOP
I4
I3
I2
I1
I5
MOV32 @XAR3, R6H
I5
I4
I3
I2
I1
I5
I4
I3
I2
I1
I5
I4
I3
I2
I1
I5
I4
I3
I2
I1
I5
I4
I3
I2
I1
(STALL)
Due to one extra NOP, I5 does not
reach R2 when I1 enters E3; thus,
forwarding is not needed.
I5
I4
I3
I2
I1
There is no change due to the
stall in the previous cycle.
I5
I4
I3
I2
I1 moves out of E3 and I5 moves to
R2. R6H has the result of R5H*R0H
and is read by I5. There is no
need to forward the result in this
case.
I5
I4
I3
I3
I3
I2
I1
Comments
FPU pipeline-->
I1
I1
Figure 3-3. Pipeline Diagram With Workaround in Place
Silicon Revision B Usage Notes and Advisories
12
TMS320F28004x Real-Time MCUs Silicon Errata
Silicon Revisions B, A, 0
SPRZ439G – JANUARY 2017 – REVISED AUGUST 2022
Copyright © 2022 Texas Instruments Incorporated