8.14.3 Clock Specifications
8.14.3.1 48 MHz Bulk Acoustic Wave (BAW) Oscillator
Measured on CC26x2RBEM-7ID reference design with T
c
= 25 °C, V
DDS
= 3.0 V, unless otherwise noted.
PARAMETER
MIN
TYP
MAX
UNIT
Clock frequency
48
MHz
Compensated clock frequency for RF PLL and Modem
-40
40
ppm
Start-up time
80
µs
(1)
Compensated clock frequency used by RF PLL and Modem. Non-RF domain (MCU and Peripherals) uncompensated frequency has
variation upto +/- 0.4% in offset and +/- 200 ppm across temperature.
(2)
Across operational temperature range, including 10 year aging at 30°C. Compensation parameters are measured in TI production and
stored in device for clock compensation.
(3)
Start-up time using the TI-provided power driver.
8.14.3.2 48 MHz Crystal Oscillator (XOSC_HF)
Measured on a Texas Instruments reference design with T
c
= 25 °C, V
DDS
= 3.0 V, unless otherwise noted.
PARAMETER
MIN
TYP
MAX
UNIT
Crystal frequency
48
MHz
ESR
Equivalent series resistance
6 pF < C
L
≤ 9 pF
20
60
Ω
ESR
Equivalent series resistance
5 pF < C
L
≤ 6 pF
80
Ω
L
M
Motional inductance, relates to the load capacitance that is used for the
crystal (C
L
in Farads)
< 3 × 10
–25
/ C
L
2
H
C
L
Crystal load capacitance
5
7
9
pF
Start-up time
200
µs
(1)
Probing or otherwise stopping the crystal while the DC/DC converter is enabled may cause permanent damage to the device.
(2)
Start-up time using the TI-provided power driver. Start-up time may increase if driver is not used.
(3)
On-chip default connected capacitance including reference design parasitic capacitance. Connected internal capacitance is changed
through software in the Customer Configuration section (CCFG).
(4)
Adjustable load capacitance is integrated into the device.
(5)
The crystal manufacturer's specification must satisfy this requirement for proper operation.
8.14.3.3 48 MHz RC Oscillator (RCOSC_HF)
Measured on a Texas Instruments reference design with T
c
= 25 °C, V
DDS
= 3.0 V, unless otherwise noted.
MIN
TYP
MAX
UNIT
Frequency
48
MHz
Uncalibrated frequency accuracy
±1
%
±0.25
%
Start-up time
5
µs
(1)
Accuracy relative to the calibration source (XOSC_HF)
8.14.3.4 2 MHz RC Oscillator (RCOSC_MF)
Measured on a Texas Instruments reference design with T
c
= 25 °C, V
DDS
= 3.0 V, unless otherwise noted.
MIN
TYP
MAX
UNIT
Calibrated frequency
2
MHz
Start-up time
5
µs
SWRS232D – FEBRUARY 2019 – REVISED FEBRUARY 2021