background image

IMPORTANT NOTICE

Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements,
and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should
obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are
sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.

TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard
warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.

TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and
applications using TI components. To minimize the risks associated with customer products and applications, customers should provide
adequate design and operating safeguards.

TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right,
or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information
published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a
warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual
property of the third party, or a license from TI under the patents or other intellectual property of TI.

Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied
by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive
business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional
restrictions.

Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all
express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not
responsible or liable for any such statements.

TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably
be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing
such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products
and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be
provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in
such safety-critical applications.

TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are
specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military
specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at
the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use.

TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are
designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated
products in automotive applications, TI will not be responsible for any failure to meet such requirements.

Following are URLs where you can obtain information on other Texas Instruments products and application solutions:

Products

Applications

Amplifiers

amplifier.ti.com

Audio

www.ti.com/audio

Data Converters

dataconverter.ti.com

Automotive

www.ti.com/automotive

DLP® Products

www.dlp.com

Broadband

www.ti.com/broadband

DSP

dsp.ti.com

Digital Control

www.ti.com/digitalcontrol

Clocks and Timers

www.ti.com/clocks

Medical

www.ti.com/medical

Interface

interface.ti.com

Military

www.ti.com/military

Logic

logic.ti.com

Optical Networking

www.ti.com/opticalnetwork

Power Mgmt

power.ti.com

Security

www.ti.com/security

Microcontrollers

microcontroller.ti.com

Telephony

www.ti.com/telephony

RFID

www.ti-rfid.com

Video & Imaging

www.ti.com/video

RF/IF and ZigBee® Solutions

www.ti.com/lprf

Wireless

www.ti.com/wireless

Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265

Copyright © 2009, Texas Instruments Incorporated

Содержание DRV8811EVM

Страница 1: ...DRV8811EVM User s Guide Literature Number SLVA344A July 2009 Revised September 2009 ...

Страница 2: ...2 SLVA344A July 2009 Revised September 2009 Submit Documentation Feedback ...

Страница 3: ...811 Evaluation Board Windows Application Software 8 2 3 Running the Windows Application Software 8 3 Windows Application 8 3 1 Menu 9 3 2 DRV8811 GPIO Control Signals 9 3 3 Updating DAC Output for Current Control VREF DECAY 10 3 4 Updating DAC Output for Decay Control DECAY 10 3 5 Operating the Stepper Motor 10 4 Schematic 12 SLVA344A July 2009 Revised September 2009 Table of Contents 3 Submit Doc...

Страница 4: ..._RD_EVM_R1p0 exe Main Screen 8 4 Acknowledgement Text Box 9 5 Signals Frame 9 6 Curent Control Frame 10 7 Current Control Frame 10 8 Step Rate 11 9 Speed Control Frame 11 10 Step Control Frame 12 4 List of Figures SLVA344A July 2009 Revised September 2009 Submit Documentation Feedback ...

Страница 5: ...nd Motor Drives This document is provided as a supplement to the DRV8811 datasheet It details the hardware implementation of the DRV8811 customer evaluation module EVM SLVA344A July 2009 Revised September 2009 Laser and Motor Drives 5 Submit Documentation Feedback ...

Страница 6: ...ands from the PC and generates control signals to the driver device and the DRV8811 device with access to all signals for a complete evaluation The DRV8811 customer EVM uses a combination of terminal blocks and test clips for the application monitoring of power The only power rail the user must supply is VM for the device s power stage VDD for logic levels is internally generated from the USB conn...

Страница 7: ...selects an analog voltage derived from the MSP430 s digital to analog converter channel 0 DAC0 Figure 2 DECAY SELECT Jumper To configure the DECAY SELECT jumper Figure 2 a selects an analog voltage derived from VDD through a voltage divider implemented as a potentiometer R6 Figure 2 b selects an analog voltage derived from the MSP430 s digital to analog converter channel 1 DAC1 There are three way...

Страница 8: ...plication is the software counterpart for the DRV8811 EVM It is in charge of connecting to the MSP430 microcontroller via a USB connection which in turn selects the proper logic state for the DRV8811 control signals The graphical user interface GUI has been designed to allow for all of the DRV8811 device s functionality to be tested without having to intervene with the hardware except for the prop...

Страница 9: ...he application the order of events should be 1 Go to Settings Port and choose the COM port where the USB virtual COM port device has been configured to work If the COM port is 4 then this step can be skipped as application defaults to COM4 2 Press Connect If the port is available the menu changes the Connect caption to Disconnect Press Disconnect to disable the serial communications 1 4 0 should r...

Страница 10: ...e output voltage and DAC_VALUE is a number from 0 to 4095 If the DRV8811 EVM has been configured to accept DECAY analog voltages through the MSP430 microcontroller interface JP6 is set to INT then the slider bar on the Current Control frame can be used to set the DECAY voltage Figure 7 Current Control Frame The MSP430F1612 12 bit DAC channel 1 is connected to the DRV8811 DECAY analog input Changin...

Страница 11: ...to reach the PPS speed Acceleration rate is an 8 bit number 0 to 255 that gets added to the current PPS speed and time base is an 8 bit number 0 to 255 that specifies how many milliseconds will elapse from one speed increase to the next Once the specified PPS speed has been achieved the acceleration stops Figure 8 Step Rate When the motor is commanded to stop the inverse of the description above o...

Страница 12: ...ontrol the stepping of the motor on a predetermined number of steps fashion The Pulse Step button allows for a single step to be issued At the same time the STEP Control check box allows the control of the STEP signal in the same fashion that other GPIO signals on the Signals frame could be set and cleared Checked stands for HI and unchecked for LO Remember that a STEP takes place when STEP goes f...

Страница 13: ...ice TI is not responsible or liable for any such statements TI products are not authorized for use in safety critical applications such as life support where a failure of the TI product would reasonably be expected to cause severe personal injury or death unless officers of the parties have executed an agreement specifically governing such use Buyers represent that they have all necessary expertis...

Отзывы: