SBAS582C – JULY 2014 – REVISED APRIL 2015
8.5.2.3.3
Range Select Registers (addresses 05h-0Ch)
Address 05h corresponds to channel 0, address 06h corresponds to channel 1, address 07h corresponds to
channel 2, address 08h corresponds to channel 3, address 09h corresponds to channel 4, address 0Ah
corresponds to channel 5, address 0Bh corresponds to channel 6, and address 0Ch corresponds to channel 7.
These registers allow the selection of input ranges for all individual channels (n = 0 to 3 for the ADS8684 and n =
0 to 7 for the ADS8688). The default value for these registers is 00h.
Figure 93. Channel n Input Range Registers
7
6
5
4
3
2
1
0
0
0
0
0
Range_CH
n
[3:0]
R-0h
R-0h
R-0h
R-0h
R/W-0h
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 15. Channel n Input Range Registers Field Descriptions
Bit
Field
Type
Reset
Description
7-4
0
R
0h
Must always be set to 0
Input range selection bits for channel n (n = 0 to 3 for the ADS8684 and n =
0 to 7 for the ADS8688).
0000 = Input range is set to ±2.5 x V
REF
3-0
Range_CH
n
[3:0]
R/W
0h
0001 = Input range is set to ±1.25 x V
REF
0010 = Input range is set to ±0.625 x V
REF
0101 = Input range is set to 0 to 2.5 x V
REF
0110 = Input range is set to 0 to 1.25 x V
REF
8.5.2.3.4
Command Read-Back Register (address = 3Fh)
This register allows the device mode of operation to be read. On execution of this command, the device outputs
the command word executed in the previous data frame. The output of the command register appears on SDO
from the 16th falling edge onwards in an MSB-first format. All information regarding the command register is
contained in the first eight bits and the last eight bits are 0 (refer to
), thus the command read-back
operation can be stopped after the 24th SCLK cycle.
Figure 94. Command Read-Back Register
7
6
5
4
3
2
1
0
COMMAND_WORD[15:8]
R-0h
LEGEND: R = Read only; -n = value after reset
Table 16. Command Read-Back Register Field Descriptions
Bit
Field
Type
Reset
Description
7-0
COMMAND_WORD[15:8]
R
0h
Command executed in previous data frame.
Copyright © 2014–2015, Texas Instruments Incorporated
51
Product Folder Links: