Texas Instruments ADS54J60 Скачать руководство пользователя страница 6

Quick Start Guide

www.ti.com

2.2.2

ADS54J60EVM Setup

Next, setup the ADS54J60EVM using the following:

1. Connect the included 5-V power supply cable to connector J9 of the EVM. Connect the red wire to

+5VDC +/- 0.1VDC of a power supply rated for at least 3 Amps. Connect the black wire to GND of the
power supply.

2. Connect the included mini-USB cable to the USB connector J8.

3. Turn on the power supply. The power draw should be around 0.66 Amps. When the board is

configured, it will draw approximately 1.35 Amps.

4. Set the analog input signal generator for 170 MHz, and about +15 dBm of power.

5. Place a narrow pass-band band-pass filter at the output of the analog signal generator to remove noise

and harmonics from the signal generator.

6. Connect the analog input signal generator to the EVM though SMA connector AINP (J2).

2.3

Software Setup Procedure

The software can be opened and configured once the hardware is properly setup.

2.3.1

ADS54J60 GUI Configuration

1. Open the ADS54Jxx EVM GUI by going to

Start Menu

All Programs

Texas Instruments ADCs

ADS54Jxx EVM GUI

.

2. Verify that the green

USB Status

indicator is lit in the top right corner of the GUI. If it is not lit, click the

Reconnect USB

button and check the

USB Status

indicator again. If it is still not lit, then verify the EVM

is connected to the computer through the included mini-USB cable.

3. Click on the

Low Level View

tab then click the

Load Config

button.

4. Navigate to

C:\Program Files(86)\Texas Instruments\ADS54Jxx EVM GUI\Configuration Files

, select

the file called

LMK_Config_Onboard_983p04_MSPS.cfg

, then click

OK

. This programs the LMK04828

to provide a 983.04 MHz clock to the ADC.

5. Verify that the LMK04828 phase lock loop (PLL) is locked by checking that the

PLL2 LOCKED

LED

(D3) is lit.

6. Once the LMK04828 PLL is locked, press SW1 (

ADC RESET

) to provide a hardware reset to the ADC.

This switch is located in the middle of the EVM.

7. In the

Low Level View

tab, click

Load Config

. Select the file called

ADS54J60_LMF_8224.cfg

and click

OK

. The ADS54J60EVM is now configured for no decimation and 8 JESD204B lanes.

6

ADS54J60EVM

SLAU629A – April 2015 – Revised January 2016

Submit Documentation Feedback

Copyright © 2015–2016, Texas Instruments Incorporated

Содержание ADS54J60

Страница 1: ...3 HSDC Pro Settings 11 4 Software Description 12 4 1 ADS54J60 EVM GUI 12 4 2 Low Level View 13 5 Alternate Hardware Configurations 14 5 1 Clocking Options 14 5 2 Analog Input Options 15 Appendix A Ju...

Страница 2: ...om leading FPGA vendors that contain an FMC connector 1 1 Required Hardware The following equipment is included in the EVM evaluation kit ADS54J60 Evaluation Board EVM Power supply cable Mini USB cabl...

Страница 3: ...ware available at www ti com tool ads54j60evm ADS54J60 datasheet SBAS706 available at www ti com product ads54j60 LMK04828 datasheet SNAS605 available at www ti com product lmk04828 TSW14J56EVM User s...

Страница 4: ...S54J60EVM It must be used to properly configure the devices on the EVM 1 Download the ADS54Jxx EVM GUI from the TI website The References section of this document contains links to find the software o...

Страница 5: ...rdware setup steps Figure 2 Quick Start Test Setup 2 2 1 TSW14J56EVM Setup First setup the TSW14J56EVM using the following steps 1 Connect the ADS54J60EVM to the TSW14J56EVM using the FMC connectors 2...

Страница 6: ...enu All Programs Texas Instruments ADCs ADS54Jxx EVM GUI 2 Verify that the green USB Status indicator is lit in the top right corner of the GUI If it is not lit click the Reconnect USB button and chec...

Страница 7: ...4 Figure 4 HSDC Pro GUI Main Panel 2 When prompted to select the capture board select the TSW14J56 whose serial number corresponds to the serial number on the TSW14J56EVM and click OK This popup can b...

Страница 8: ...Output Data Rate field at the bottom left corner then click outside this box or press return on the PC keyboard 8 The GUI displays the new lane rate of the SerDes interface based off of the sample ra...

Страница 9: ...hieved then see the Quick Start Troubleshooting section of this document Figure 5 Channel 1 Data Capture Results from Quick Start Procedure Table 1 Quick Start Performance Measurements Result Measured...

Страница 10: ...r s Device Manager and verify that a USB Serial Device is recognized when the EVM is connected to the PC Verify that the green USB Status LED light in the top right corner of the GUI is lit If it is n...

Страница 11: ...tter SNR results The clock and analog inputs must be frequency locked such as through 10 MHz references in order to achieve coherency 3 3 HSDC Pro Settings HSDC Pro has some settings that can help imp...

Страница 12: ...e Low Level View tab to load configuration files LMK04828 Enables control of many of the LMK04828 features Configuration files can be used to setup the LMK04828 in known working configurations however...

Страница 13: ...all registers shown in the Register Map with the values shown in the Register Map log The log can be viewed by double left clicking in the bottom left status bar of this page Read Register button Read...

Страница 14: ...SYSREF signals to both boards This option provides the best performance as long as the clock source has better phase noise performance than the LMK04828 The source of the EXT ADC clock must be synchro...

Страница 15: ...sired frequencies To use this mode load one of the configuration files named LMK_Config_Onboard_xxxx_MSPS cfg where xxxx corresponds to the desired ADC sampling rate A 10 MHz signal can be brought int...

Страница 16: ...FMC Default is diff Shunt pins 2 3 A 2 Connector Descriptions The EVM connectors and their function are described in Table 7 Table 7 Connector Descriptions Connector Description J2 Channel A positive...

Страница 17: ...Quick Start Test Setup image 5 Added Channel 1 Data Capture Results from Quick Start Procedure image 9 Added Low Level View section 13 Added Alternate Hardware Configurations section to reflect change...

Страница 18: ...ing the warranty period to the address designated by TI and that are determined by TI not to conform to such warranty If TI elects to repair or replace such EVM TI shall have a reasonable time to repa...

Страница 19: ...transmitter has been approved by Industry Canada to operate with the antenna types listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indic...

Страница 20: ...ified allowable ranges some circuit components may have elevated case temperatures These components include but are not limited to linear regulators switching transistors pass transistors current sens...

Страница 21: ...REMOVAL OR REINSTALLATION ANCILLARY COSTS TO THE PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES RETESTING OUTSIDE COMPUTER TIME LABOR COSTS LOSS OF GOODWILL LOSS OF PROFITS LOSS OF SAVINGS LOSS OF USE L...

Страница 22: ...sponsible for compliance with all legal regulatory and safety related requirements concerning its products and any use of TI components in its applications notwithstanding any applications related inf...

Отзывы: