FCC Interference Statement for Class B EVM devices

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more
of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

3.2

Canada

3.2.1

For EVMs issued with an Industry Canada Certificate of Conformance to RSS-210

Concerning EVMs Including Radio Transmitters:

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may
cause undesired operation of the device.

Concernant les EVMs avec appareils radio:

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation
est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit
accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.

Concerning EVMs Including Detachable Antennas:

Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser)
gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type
and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for
successful communication. This radio transmitter has been approved by Industry Canada to operate with the antenna types
listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indicated.
Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited
for use with this device.

Concernant les EVMs avec antennes détachables

Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et
d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage
radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope
rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. Le
présent émetteur radio a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés dans le
manuel d’usage et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne
non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de
l'émetteur

3.3

Japan

3.3.1

Notice for EVMs delivered in Japan:

Please see

http://www.tij.co.jp/lsds/ti_ja/general/eStore/notice_01.page

日本国内に

輸入される評価用キット、ボードについては、次のところをご覧ください。

http://www.tij.co.jp/lsds/ti_ja/general/eStore/notice_01.page

3.3.2

Notice for Users of EVMs Considered “Radio Frequency Products” in Japan:

EVMs entering Japan may not be certified

by TI as conforming to Technical Regulations of Radio Law of Japan.

If User uses EVMs in Japan, not certified to Technical Regulations of Radio Law of Japan, User is required by Radio Law of
Japan to follow the instructions below with respect to EVMs:

1.

Use EVMs in a shielded room or any other test facility as defined in the notification #173 issued by Ministry of Internal
Affairs and Communications on March 28, 2006, based on Sub-section 1.1 of Article 6 of the Ministry’s Rule for
Enforcement of Radio Law of Japan,

2.

Use EVMs only after User obtains the license of Test Radio Station as provided in Radio Law of Japan with respect to
EVMs, or

3.

Use of EVMs only after User obtains the Technical Regulations Conformity Certification as provided in Radio Law of Japan
with respect to EVMs. Also, do not transfer EVMs, unless User gives the same notice above to the transferee. Please note
that if User does not follow the instructions above, User will be subject to penalties of Radio Law of Japan.

SPACER

SPACER

SPACER

SPACER

SPACER

Содержание ADS54J60

Страница 1: ...3 HSDC Pro Settings 11 4 Software Description 12 4 1 ADS54J60 EVM GUI 12 4 2 Low Level View 13 5 Alternate Hardware Configurations 14 5 1 Clocking Options 14 5 2 Analog Input Options 15 Appendix A Ju...

Страница 2: ...om leading FPGA vendors that contain an FMC connector 1 1 Required Hardware The following equipment is included in the EVM evaluation kit ADS54J60 Evaluation Board EVM Power supply cable Mini USB cabl...

Страница 3: ...ware available at www ti com tool ads54j60evm ADS54J60 datasheet SBAS706 available at www ti com product ads54j60 LMK04828 datasheet SNAS605 available at www ti com product lmk04828 TSW14J56EVM User s...

Страница 4: ...S54J60EVM It must be used to properly configure the devices on the EVM 1 Download the ADS54Jxx EVM GUI from the TI website The References section of this document contains links to find the software o...

Страница 5: ...rdware setup steps Figure 2 Quick Start Test Setup 2 2 1 TSW14J56EVM Setup First setup the TSW14J56EVM using the following steps 1 Connect the ADS54J60EVM to the TSW14J56EVM using the FMC connectors 2...

Страница 6: ...enu All Programs Texas Instruments ADCs ADS54Jxx EVM GUI 2 Verify that the green USB Status indicator is lit in the top right corner of the GUI If it is not lit click the Reconnect USB button and chec...

Страница 7: ...4 Figure 4 HSDC Pro GUI Main Panel 2 When prompted to select the capture board select the TSW14J56 whose serial number corresponds to the serial number on the TSW14J56EVM and click OK This popup can b...

Страница 8: ...Output Data Rate field at the bottom left corner then click outside this box or press return on the PC keyboard 8 The GUI displays the new lane rate of the SerDes interface based off of the sample ra...

Страница 9: ...hieved then see the Quick Start Troubleshooting section of this document Figure 5 Channel 1 Data Capture Results from Quick Start Procedure Table 1 Quick Start Performance Measurements Result Measured...

Страница 10: ...r s Device Manager and verify that a USB Serial Device is recognized when the EVM is connected to the PC Verify that the green USB Status LED light in the top right corner of the GUI is lit If it is n...

Страница 11: ...tter SNR results The clock and analog inputs must be frequency locked such as through 10 MHz references in order to achieve coherency 3 3 HSDC Pro Settings HSDC Pro has some settings that can help imp...

Страница 12: ...e Low Level View tab to load configuration files LMK04828 Enables control of many of the LMK04828 features Configuration files can be used to setup the LMK04828 in known working configurations however...

Страница 13: ...all registers shown in the Register Map with the values shown in the Register Map log The log can be viewed by double left clicking in the bottom left status bar of this page Read Register button Read...

Страница 14: ...SYSREF signals to both boards This option provides the best performance as long as the clock source has better phase noise performance than the LMK04828 The source of the EXT ADC clock must be synchro...

Страница 15: ...sired frequencies To use this mode load one of the configuration files named LMK_Config_Onboard_xxxx_MSPS cfg where xxxx corresponds to the desired ADC sampling rate A 10 MHz signal can be brought int...

Страница 16: ...FMC Default is diff Shunt pins 2 3 A 2 Connector Descriptions The EVM connectors and their function are described in Table 7 Table 7 Connector Descriptions Connector Description J2 Channel A positive...

Страница 17: ...Quick Start Test Setup image 5 Added Channel 1 Data Capture Results from Quick Start Procedure image 9 Added Low Level View section 13 Added Alternate Hardware Configurations section to reflect change...

Страница 18: ...ing the warranty period to the address designated by TI and that are determined by TI not to conform to such warranty If TI elects to repair or replace such EVM TI shall have a reasonable time to repa...

Страница 19: ...transmitter has been approved by Industry Canada to operate with the antenna types listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indic...

Страница 20: ...ified allowable ranges some circuit components may have elevated case temperatures These components include but are not limited to linear regulators switching transistors pass transistors current sens...

Страница 21: ...REMOVAL OR REINSTALLATION ANCILLARY COSTS TO THE PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES RETESTING OUTSIDE COMPUTER TIME LABOR COSTS LOSS OF GOODWILL LOSS OF PROFITS LOSS OF SAVINGS LOSS OF USE L...

Страница 22: ...sponsible for compliance with all legal regulatory and safety related requirements concerning its products and any use of TI components in its applications notwithstanding any applications related inf...