Table 1. ADS1298RECG-FE Default Jumper/Switch Configuration
Jumper
Default Position
Description
JP1
Installed
RLD feedback
JP2
Installed 1-2
AVDD selected for bipolar supply operation selected (AVDD = +2.5V)
JP3
Header Not Installed
External Vref buffer not connected
JP4
Installed
EVM +5V provided from J4 (power header)
JP5
Open
PWDN pin controlled from J5 header (pulled up to DVDD)
JP6 to JP14
Header Not Installed (Pins 1-2
shorted on PCB)
DC-coupled input signals
JP15
Installed 2-3
Shield drive is open
JP16
Installed
Wilson Central Terminal (WCT) connected to INM for CH1 and CH4-8
JP17
Header Not Installed
ECG shield drive is connected to AGND
JP18
Installed 2-3
CLK
connected to OSC1
JP19
Installed 1-2
OSC1 enabled
JP20
Installed 2-3
AVSS selected for bipolar supply operation (AVSS = -2.5V)
JP21
Installed 1-2
CS
connected to DSP via J3.1
JP22
Installed 2-3
START
comes from J3.14
JP23
Installed 1-2
CLKSEL
set to 0
JP24
Installed 2-3
DVDD supply = 3.3V
JP25
Header Not Installed
No external reference selected
JP26
Installed 1-2 (top)
WCT connected to CH8- input
Installed 3-4 (bottom)
ECG_V1 connected to CH8+ input
JP27
Installed 1-2 (top)
WCT connected to CH7- input
Installed 3-4 (bottom)
ECG_V5 connected to CH7+ input
JP28
Installed 1-2 (top)
WCT connected to CH6- input
Installed 3-4 (bottom)
ECG_V4 connected to CH6+ input
JP29
Installed 1-2 (top)
WCT connected to CH5- input
Installed 3-4 (bottom)
ECG_V3 connected to CH5+ input
JP30
Installed 1-2 (top)
WCT connected to CH4- input
Installed 3-4 (bottom)
ECG_V2 connected to CH4+ input
JP31
Installed 1-2 (top)
ECG_RA connected to CH3- input
Installed 3-4 (bottom)
ECG_LL connected to CH3+ input
JP32
Installed 1-2 (top)
ECG_RA connected to CH2- input
Installed 3-4 (bottom)
ECG_LA connected to CH2+ input
JP33
Open 1-2 (top)
Not connected
Open 3-4
Not connected
Installed 5-6
CH1- input connected to source of JP35
Installed 7-8 (bottom)
CH1+ input connected to source of JP36
JP34
Installed 1-2
Connected onboard RESP circuit to CH1- signal input mux (RESPMOD-)
JP35
Installed 1-2
Connected onboard RESP circuit to CH1+ signal input mux ()
JP36
Installed 1-2
RESP control signal for U11/U12 controlled by MSP430 (U14)