Receiver driers & accumulators:
Both driers and accumulators include fine
screens and desiccant. The flow of refrigerant
through these components is not a straight
path, so they can not be flushed. These
components
always require replacement
.
Compressors:
Compressors are definitively sensible to the
quality and the cleanness of the lubricant. In
fact the A/C system contains oil which is
transported by the refrigerant in order to
lubricate the compressor. (like a two strokes
engine). Contaminated oil is not giving the
required lubrication, as dirt particles are
acting as abrasive paper, damaging the
moving components.
Contamination with solid particles will always
drive the
compressor to failure
.
Hoses and tubing:
Restrictions and junction points of connecting
hoses and tubing are also strategic areas
which can retain contaminations and be
subject
to blockage
.