INTRODUCTION TO FLUSHING MODES:
SINGLE FLUSHING:
T
his program mode is performing one flushing cycle. This configuration
is used in case of small contamination and / or simple oil / UV additive removing.
MULTIPLE FLUSHING:
This program mode is performing tree consecutive flushing cycles.
(Except vacuum, this will be performed only one time at the beginning). This configuration is
used in case of heavy contamination due to a major failure as compressor damage.
After having selected the required flushing mode,
The Display shows:
C o n n e c t H P s e r v i c e
h o s e t o s y s t e m
C o n n e c t L P s e r v i c e
h o s e t o csa n i s t e r
Press
Enter
to confirm.
The Display shows:
O p e n L P / H P v a l v e s .
E N T E R t o c o n f i r m .
Press
Enter
to confirm.
The vacuum phase starts automatically…
The Display shows:
F l u s h i n g
V a c u u m .
T i m e 0 0 : 0 0 : 0 0
m B . x x x x
Vaccum timer and absolute pressure in the system are indicated.
Default vacuum time is
5 minutes
, but it can be shorted by
pressing
UP
/
DOWN.
You can also completely cancel and
quit the program by pressing the
Stop
button.