TPMC816 V.2.1 User Manual Issue 2.1.0
Page 22 of 22
7.2 Mezzanine Card Connector P14
Pin-No.
Function
1 NC
2
Ground channel 0
3
Low level CAN voltage input/output
channel 0
Selectable: CAN high speed or mod. RS485
4
High level CAN voltage input/output
channel 0
Selectable: CAN high speed or mod. RS485
5
Ground channel 0
6 NC
7 NC
8 NC
9 NC
10 NC
11
Ground channel 1
12
Low level CAN voltage input/output
channel 1
Selectable: CAN high speed or mod. RS485
13
High level CAN voltage input/output
channel 1
Selectable: CAN high speed or mod. RS485
14
Ground channel 1
15 NC
16..32 NC
Table 7-3 : Mezzanine Card Connector P14
Please note that on the TPMC816-1x, the P14 back I/O connector is always populated and is
connected in parallel to the front I/O connectors.
Do not use these modules on carrier boards where P14/J14 is reserved for other system
signals but PMC I/O. Ask support for special board options with front I/O only in this case.
For a CAN bus channel, do either use front I/O or back I/O. Do not use both front I/O and back
I/O at the same time for a CAN bus channel.