TPMC816 V.2.1 User Manual Issue 2.1.0
Page 19 of 22
6 Installation
6.1 CAN bus Termination
Each end of a CAN bus must be terminated by a 120 ohms resistor between the CAN bus lines CAN
high and CAN low.
This termination could be activated by installing jumper on the jumper field J4/J5 and J8/J9. Because
of split termination there are two jumpers for each channel.
Bus line termination for CAN bus channel 0 active: Jumper J4 + J5 (1-2) installed
Bus line termination for CAN bus channel 1 active: Jumper J8 + J9 (1-2) installed
To set the termination of a CAN bus I/O channel, always use both jumpers for that channel.
6.2 Physical Interface
Select the physical interface by installing jumper on jumper field J1 – J4.
CAN High Speed
Mod. RS485
Channel 0
Jumper J2 ( 1-3 )
Jumper J2 ( 2-4 )
Jumper J3 ( 1-3 )
Jumper J3 ( 2-4 )
Jumper J2 ( 3-5 )
Jumper J2 ( 4-6 )
Jumper J3 ( 3-5 )
Jumper J3 ( 4-6 )
Channel 1
Jumper J6 ( 1-3 )
Jumper J6 ( 2-4 )
Jumper J7 ( 1-3 )
Jumper J7 ( 2-4 )
Jumper J6 ( 3-5 )
Jumper J6 ( 4-6 )
Jumper J7 ( 3-5 )
Jumper J7 ( 4-6 )
Table 6-1 : Physical Interface Selection
Figure 6-1 : Jumper Location TPMC816