CHAPTER 4
OPERATION
4-17
DN-109AT, DN-119AT, DN-129AT and DN-189AT display series
4.5.3.
Ethernet parameter configuration
The Ethernet parameters, like the IP address, the Gateway, the subnet mask, etc can be
configured manually or automatically through DHCP. Previously, the user must know the IP address
he wants for the display. It is highly recommended to change the IP address from the default.
Once the user has accessed the Ethernet tab of the display webpage, configure the
parameters manually or activate the DHCP protocol for the display to request all the network
parameters automatically. When clicking the button “validate”, the system saves the changes and
reboots. If the parameters are put manually, the work is finished.
On the other side, the display may have changed the IP address. This IP address can be
checked (and changed) through parameters or the “Display Discoverer”. The DHCP can be left
enabled or disabled. If the user modifies the IP address, the DHCP protocol will be disabled.
Go to the web
Go to Ethernet tab
Write parameters in
the fields and save
Manual configuration
Activate the DHCP
option and let the
display reset
Automatic configuration
Check the IP
Go to the web,
Ethernet tab
IP not valid
Change the IP
through parameter
menú or the
“Display Discoverer”
IP valid
Disable the DHCP
option and save